Search Results (3079 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-33025 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-40628 2026-04-15 N/A
SQL injection vulnerability in DomainsPRO 1.2. This vulnerability could allow an attacker to retrieve, create, update and delete databases via the “d” parameter in the “/article.php” endpoint.
CVE-2025-1981 2026-04-15 N/A
Improper neutralization of input provided by a low-privileged user into a file search functionality in Ready_'s Invoices module allows for SQL Injection attacks.
CVE-2024-10576 1 Infinix Mobile 1 Com.transmission.agingfunction 2026-04-15 N/A
Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions.  After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.
CVE-2024-13985 2026-04-15 N/A
A command injection vulnerability in Dahua EIMS versions prior to 2240008 allows unauthenticated remote attackers to execute arbitrary system commands via the capture_handle.action interface. The flaw stems from improper input validation in the captureCommand parameter, which is processed without sanitization or authentication. By sending crafted HTTP requests, attackers can inject OS-level commands that are executed on the server, leading to full system compromise. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-04-06 UTC.
CVE-2025-8311 1 Dotcms 1 Dotcms 2026-04-15 N/A
dotCMS versions 24.03.22 and after, identified a Boolean-based blind SQLi vulnerability in the /api/v1/contenttype endpoint. This endpoint uses the sites query parameter, which accepts a comma-separated list of site identifiers or keys. The vulnerability was triggered via the sites parameter, which was directly concatenated into a SQL query without proper sanitization. Exploitation allowed an authenticated attacker with low privileges to extract data from database, perform privilege escalation, or trigger denial-of-service conditions. The vulnerability was verified using tools such as SQLMap and confirmed to allow full database exfiltration and potential denial-of-service conditions via crafted payloads. The vulnerability is fixed in the following versions of dotCMS stack: 25.08.14 / 25.07.10-1v2 LTS / 24.12.27v10 LTS / 24.04.24v21 LTS
CVE-2025-30055 1 Cgm 1 Clininet 2026-04-15 N/A
The "system" function receives untrusted input from the user. If the "EnableJSCaching" option is enabled, it is possible to execute arbitrary code provided as the "Module" parameter.
CVE-2024-36456 1 Broadcom 1 Symantec Privileged Access Management 2026-04-15 N/A
This vulnerability allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by uploading a specially crafted PAM upgrade file.
CVE-2024-41988 1 Tem 1 Opera Plus Fm Family Transmitter 2026-04-15 N/A
TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
CVE-2025-30091 2026-04-15 N/A
In Tiny MoxieManager PHP before 4.0.0, remote code execution can occur in the installer command. This vulnerability allows unauthenticated attackers to inject and execute arbitrary code. Attacker-controlled data to InstallCommand can be inserted into config.php, and InstallCommand is available after an installation has completed.
CVE-2024-37998 2026-04-15 9.8 Critical
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.
CVE-2025-24800 2026-04-15 N/A
Hyperbridge is a hyper-scalable coprocessor for verifiable, cross-chain interoperability. A critical vulnerability was discovered in the ismp-grandpa crate, that allowed a malicious prover easily convince the verifier of the finality of arbitrary headers. This could be used to steal funds or compromise other kinds of cross-chain applications. This vulnerability is fixed in 15.0.1.
CVE-2024-41798 1 Siemens 1 Sentron Pac3200 2026-04-15 9.8 Critical
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
CVE-2024-54143 1 Openwrt 1 Asu 2026-04-15 N/A
openwrt/asu is an image on demand server for OpenWrt based distributions. The request hashing mechanism truncates SHA-256 hashes to only 12 characters. This significantly reduces entropy, making it feasible for an attacker to generate collisions. By exploiting this, a previously built malicious image can be served in place of a legitimate one, allowing the attacker to "poison" the artifact cache and deliver compromised images to unsuspecting users. This can be combined with other attacks, such as a command injection in Imagebuilder that allows malicious users to inject arbitrary commands into the build process, resulting in the production of malicious firmware images signed with the legitimate build key. This has been patched with 920c8a1.
CVE-2025-4558 2026-04-15 9.8 Critical
The GPM from WormHole Tech has an Unverified Password Change vulnerability, allowing unauthenticated remote attackers to change any user's password and use the modified password to log into the system.
CVE-2025-4559 2026-04-15 9.8 Critical
The ISOinsight from Netvision has a SQL Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary SQL commands to read, modify, and delete database contents.
CVE-2025-58428 1 Veeder 1 Tls4b Automatic Tank Gauge System 2026-04-15 9.9 Critical
The TLS4B ATG system's SOAP-based interface is vulnerable due to its accessibility through the web services handler. This vulnerability enables remote attackers with valid credentials to execute system-level commands on the underlying Linux system. This could allow the attacker to achieve remote command execution, full shell access, and potential lateral movement within the network.
CVE-2025-32469 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-10264 1 Digiever 7 Ds-1200, Ds-16x00, Ds-2100 and 4 more 2026-04-15 10 Critical
Certain models of NVR developed by Digiever has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remoter attackers to access the system configuration file and obtain plaintext credentials of the NVR and its connected cameras.
CVE-2025-10364 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.