| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability in Cisco Unified Intelligence Center could allow an authenticated, remote attacker to elevate privileges to Administrator for a limited set of functions on an affected system.
This vulnerability is due to insufficient server-side validation of user-supplied parameters in API or HTTP requests. An attacker could exploit this vulnerability by submitting a crafted API or HTTP request to an affected system. A successful exploit could allow the attacker to access, modify, or delete data beyond the sphere of their intended access level, including obtaining potentially sensitive information stored in the system. |
| The powermail extension for TYPO3 allows Insecure Direct Object Reference resulting in download of arbitrary files from the webserver. This issue affects powermail version 12.0.0 up to 12.5.2 and version 13.0.0 |
| Insecure Direct Object Reference (IDOR) vulnerability in Liner thru 2025-06-03 allows attackers to gain sensitive information via crafted space_id, thread_id, and message_id parameters to the v1/space/{space_id}/thread/{thread_id}/message/{message_id} endpoint. |
| Insecure Direct Object Reference (IDOR) vulnerability in Dippy (chat.dippy.ai) v2 allows attackers to gain sensitive information via the conversation_id parameter to the conversation_history endpoint. |
| A vulnerability, which was classified as problematic, was found in thinkgem JeeSite up to 5.12.0. Affected is the function select of the file src/main/java/com/jeesite/modules/cms/web/SiteController.java of the component Site Controller. The manipulation of the argument redirect leads to open redirect. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The patch is identified as 3d06b8d009d0267f0255acc87ea19d29d07cedc3. It is recommended to apply a patch to fix this issue. |
| A vulnerability classified as problematic was found in thinkgem JeeSite up to 5.12.0. This vulnerability affects the function sso of the file src/main/java/com/jeesite/modules/sys/web/SsoController.java. The manipulation of the argument redirect leads to open redirect. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The patch is identified as 3d06b8d009d0267f0255acc87ea19d29d07cedc3. It is recommended to apply a patch to fix this issue. |
| An open redirect vulnerability has been identified in Grafana OSS organization switching functionality.
Prerequisites for exploitation:
- Multiple organizations must exist in the Grafana instance
- Victim must be on a different organization than the one specified in the URL |
| agorum Software GmbH Agorum core open v11.9.2 & v11.10.1 was discovered to contain an XML External Entity (XXE) via the RSSReader endpoint. This vulnerability allows attackers to access sensitive data via providing a crafted XML input. |
| An open redirect vulnerability has been identified in Grafana OSS that can be exploited to achieve XSS attacks. The vulnerability was introduced in Grafana v11.5.0.
The open redirect can be chained with path traversal vulnerabilities to achieve XSS.
Fixed in versions 12.0.2+security-01, 11.6.3+security-01, 11.5.6+security-01, 11.4.6+security-01 and 11.3.8+security-01 |
| Authorization Bypass Through User-Controlled Key vulnerability in Vidco Software VOC TESTER allows Forceful Browsing.This issue affects VOC TESTER: before 12.41.0. |
| Authorization Bypass Through User-Controlled Key vulnerability in Turpak Automatic Station Monitoring System allows Privilege Escalation.This issue affects Automatic Station Monitoring System: before 5.0.6.51. |
| The EAI developed by Digiwin has a Privilege Escalation vulnerability, allowing remote attackers with regular privileges to elevate their privileges to administrator level via a specific API. |
| Authorization Bypass Through User-Controlled Key vulnerability in PAVO Inc. PAVO Pay allows Exploitation of Trusted Identifiers.This issue affects PAVO Pay: before 13.05.2025. |
| A vulnerability was found in Mercusys MW301R 1.0.2 Build 190726 Rel.59423n. It has been declared as problematic. This vulnerability affects unknown code of the component Web Interface. The manipulation of the argument code leads to weak password recovery. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Authorization Bypass Through User-Controlled Key vulnerability in Turtek Software Eyotek allows Exploitation of Trusted Identifiers.This issue affects Eyotek: before 11.03.2025. |
| WordPress 3.5 through 6.8.2 allows remote attackers to guess titles of private and draft posts via pingback.ping XML-RPC requests. NOTE: the Supplier is not changing this behavior. |
| Authorization Bypass Through User-Controlled Key vulnerability in Turtek Software Eyotek allows Exploitation of Trusted Identifiers.This issue affects Eyotek: before 23.06.2025. |
| Authorization Bypass Through User-Controlled Key vulnerability in Akbim Software Online Exam Registration allows Exploitation of Trusted Identifiers.This issue affects Online Exam Registration: before 14.03.2025. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| Use of Multiple Resources with Duplicate Identifier (CWE-694) in the Controller 6000 and Controller 7000 Platforms could allow an attacker with physical access to HBUS communication cabling to perform a Denial-of-Service attack against HBUS connected devices, require a device reboot to resolve.
This issue affects: Controller 6000 and Controller 7000 firmware versions 9.10 prior to vCR9.10.241108a (distributed in 9.10.2149 (MR4)), 9.00 prior to vCR9.00.241108a (distributed in 9.00.2374 (MR5)), 8.90 prior to vCR8.90.241107a (distributed in 8.90.2356 (MR6)), all versions of 8.80 and prior. |