| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment. |
| NATS-Server is a High-Performance server for NATS.io, the cloud and edge native messaging system. In versions starting from 2.2.0 but prior to 2.10.27 and 2.11.1, the management of JetStream assets happens with messages in the $JS. subject namespace in the system account; this is partially exposed into regular accounts to allow account holders to manage their assets. Some of the JS API requests were missing access controls, allowing any user with JS management permissions in any account to perform certain administrative actions on any JS asset in any other account. At least one of the unprotected APIs allows for data destruction. None of the affected APIs allow disclosing stream contents. This vulnerability is fixed in v2.11.1 or v2.10.27. |
| An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| Incorrect access control in the fingerprint authentication mechanism of Bitdefender Mobile Security v4.11.3-gms allows attackers to bypass fingerprint authentication due to the use of a deprecated API. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could
allow an attacker to create an administrator account without knowing any
existing credentials. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp. |
| A remote code execution vulnerability exists in CryptoLog (PHP version, discontinued since 2009) due to a chained exploitation of SQL injection and command injection vulnerabilities. An unauthenticated attacker can gain shell access as the web server user by first exploiting a SQL injection flaw in login.php to bypass authentication, followed by command injection in logshares_ajax.php to execute arbitrary operating system commands.
The login bypass is achieved by submitting crafted SQL via the user POST parameter. Once authenticated, the attacker can abuse the lsid POST parameter in the logshares_ajax.php endpoint to inject and execute a command using $(...) syntax, resulting in code execution under the web context.
This exploitation path does not exist in the ASP.NET version of CryptoLog released since 2009. |
| An unauthenticated command injection vulnerability exists in Serviio Media Server versions 1.4 through 1.8 on Windows, in the /rest/action API endpoint exposed by the console component (default port 23423). The checkStreamUrl method accepts a VIDEO parameter that is passed unsanitized to a call to cmd.exe, enabling arbitrary command execution under the privileges of the web server. No authentication is required to exploit this issue, as the REST API is exposed by default and lacks access controls. |
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. |
| A low privileged remote attacker may modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| NUP Portal developed by NewType Infortech has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly upload files. If the attacker manages to bypass the file extension restrictions, they could upload a webshell and execute it on the server side. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |