| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use of Hard-Coded Credentials issue exists in MZK-DP300N version 1.07 and earlier, which may allow an attacker within the local network to log in to the affected device via Telnet and execute arbitrary commands. |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| AL-KO Robolinho Update Software has hard-coded AWS Access and Secret keys that allow anyone to access AL-KO's AWS bucket. Using the keys directly might give the attacker greater access than the app itself. Key grants AT LEAST read access to some of the objects in bucket.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only versions 8.0.21.0610 and 8.0.22.0524 were tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A vulnerability was identified in MEPIS RM, an industrial
software product developed by Metronik. The application contained a hardcoded
cryptographic key within the Mx.Web.ComponentModel.dll component. When the
option to store domain passwords was enabled, this key was used to encrypt user
passwords before storing them in the application’s database. An attacker with
sufficient privileges to access the database could extract the encrypted
passwords, decrypt them using the embedded key, and gain unauthorized access to
the associated ICS/OT environment. |
| The Civi - Job Board & Freelance Marketplace WordPress Theme plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 2.1.4 via hard-coded credentials. This makes it possible for unauthenticated attackers to extract sensitive data including LinkedIn client and secret keys. |
| A hardcoded credential vulnerability exists in the Blue Angel Software Suite deployed on embedded Linux systems. The application contains multiple known default and hardcoded user accounts that are not disclosed in public documentation. These accounts allow unauthenticated or low-privilege attackers to gain administrative access to the device’s web interface. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-26 UTC. |
| Storage credentials are hardcoded in the mobile app and device firmware. These credentials do not adequately limit end user permissions and do not expire within a reasonable amount of time. This vulnerability may grant unauthorized access to production storage containers. |
| GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechanism. Attackers can bypass login controls to access administrative functions and sensitive switch configuration without valid credentials. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information. |
| In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessible over the network on TCP port 5432. An attacker can use the hardcoded credentials to authenticate remotely, gaining superuser access to the database. This allows creation of administrative users for the web interface, extraction of password hashes, and execution of arbitrary OS commands. |
| A hardcoded cryptographic key within the configuration mechanism on TP-Link Archer NX200, NX210, NX500 and NX600 enables decryption and re-encryption of device configuration data. An authenticated attacker may decrypt configuration files, modify them, and re-encrypt them, affecting the confidentiality and integrity of device configuration data. |
| Use of Hard-coded Credentials vulnerability in Microchip Time Provider 4100 allows Malicious Manual Software Update.This issue affects Time Provider 4100: before 2.5.0. |
| A Use of Hard-coded Credentials vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts. |
| IBM Concert 1.0.0 through 2.2.0 contains hard-coded credentials that could be obtained by a local user. |
| HCL Aftermarket DPC is affected by Hardcoded Sensitive Data which allows attacker to gain access to the source code or if it is stored in insecure repositories, they can easily retrieve these hardcoded secrets. |
| HCL Aftermarket DPC is affected by SQL Injection which allows attacker to exploit this vulnerability to retrieve sensitive information from the database. |
| A use of hard-coded credentials vulnerability has been reported to affect QuNetSwitch. The remote attackers can then exploit the vulnerability to gain unauthorized access.
We have already fixed the vulnerability in the following version:
QuNetSwitch 2.0.5.0906 and later |
| Use of hard coded credentials in GoHarbor Harbor version 2.15.0 and below, allows attackers to use the default password and gain access to the web UI. |
| Use of hard-coded credentials in Klinika XP and KlinikaXP Insertino allowed an unauthorized attacker access to several internal services. Critically, this included access to the FTP server that hosted the application's update packages. The attacker with these credentials could upload a malicious update file, which then may have been distributed and installed on client machines as a legitimate update.
This issue affects KlinikaXP: before 5.39.01.01. and KlinikaXP Insertino before 3.1.0.1
Beside removing the hardcoded credentials from the code, previously exposed credentials were also rotated preventing further attack attempts. |