Export limit exceeded: 395703 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (681 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-34273 | 1 Jwtk | 1 Njwt | 2026-04-15 | 5.9 Medium |
| njwt up to v0.4.0 was discovered to contain a prototype pollution in the Parser.prototype.parse method. | ||||
| CVE-2024-57072 | 2026-04-15 | 7.5 High | ||
| A prototype pollution in the lib.requireFromString function of module-from-string v3.3.1 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. | ||||
| CVE-2025-62410 | 1 Capricorn86 | 1 Happy-dom | 2026-04-15 | 10.0 Critical |
| In versions before 20.0.2, it was found that --disallow-code-generation-from-strings is not sufficient for isolating untrusted JavaScript in happy-dom. The untrusted script and the rest of the application still run in the same Isolate/process, so attackers can deploy prototype pollution payloads to hijack important references like "process" in the example below, or to hijack control flow via flipping checks of undefined property. This vulnerability is due to an incomplete fix for CVE-2025-61927. The vulnerability is fixed in 20.0.2. | ||||
| CVE-2025-57354 | 2026-04-15 | 6.5 Medium | ||
| A vulnerability exists in the 'counterpart' library for Node.js and the browser due to insufficient sanitization of user-controlled input in translation key processing. The affected versions prior to 0.18.6 allow attackers to manipulate the library's translation functionality by supplying maliciously crafted keys containing prototype chain elements (e.g., __proto__ ), leading to prototype pollution. This weakness enables adversaries to inject arbitrary properties into the JavaScript Object prototype through the first parameter of the translate method when combined with specific separator configurations, potentially resulting in denial-of-service conditions or remote code execution in vulnerable applications. The issue arises from the library's failure to properly validate or neutralize special characters in translation key inputs before processing. | ||||
| CVE-2025-62517 | 1 Rollbar | 1 Rollbar | 2026-04-15 | 5.9 Medium |
| Rollbar.js offers error tracking and logging from Javascript to Rollbar. In versions before 2.26.5 and from 3.0.0-alpha1 to before 3.0.0-beta5, there is a prototype pollution vulnerability in merge(). If application code calls rollbar.configure() with untrusted input, prototype pollution is possible. This issue has been fixed in versions 2.26.5 and 3.0.0-beta5. A workaround involves ensuring that values passed to rollbar.configure() do not contain untrusted input. | ||||
| CVE-2025-55195 | 1 Denoland | 1 Std | 2026-04-15 | 7.3 High |
| @std/toml is the Deno Standard Library. Prior to version 1.0.9, an attacker can pollute the prototype chain in Node.js runtime and Browser when parsing untrusted TOML data, thus achieving Prototype Pollution (PP) vulnerability. This is because the library is merging an untrusted object with an empty object, which by default the empty object has the prototype chain. This issue has been patched in version 1.0.9. | ||||
| CVE-2024-57063 | 2026-04-15 | 7.5 High | ||
| A prototype pollution in the lib function of php-date-formatter v1.3.6 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. | ||||
| CVE-2024-57067 | 2026-04-15 | 7.5 High | ||
| A prototype pollution in the lib.parse function of dot-qs v0.2.0 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. | ||||
| CVE-2025-31929 | 2026-04-15 | 4.2 Medium | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. | ||||
| CVE-2023-52891 | 1 Siemens | 6 Simatic Energy Manager Basic, Simatic Energy Manager Pro, Simatic Ipc Diagbase and 3 more | 2026-04-15 | 5.3 Medium |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. | ||||
| CVE-2024-24293 | 1 Miguelcastillo | 1 Bit-loader | 2026-04-15 | 8.8 High |
| A Prototype Pollution issue in MiguelCastillo @bit/loader v.10.0.3 allows an attacker to execute arbitrary code via the M function e argument in index.js. | ||||
| CVE-2024-33519 | 2026-04-15 | 7.2 High | ||
| A vulnerability in the web-based management interface of HPE Aruba Networking EdgeConnect SD-WAN gateway could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise. | ||||
| CVE-2025-53626 | 2026-04-15 | 6.1 Medium | ||
| pdfme is a TypeScript-based PDF generator and React-based UI. The expression evaluation feature in pdfme 5.2.0 to 5.4.0 contains critical vulnerabilities allowing sandbox escape leading to XSS and prototype pollution attacks. This vulnerability is fixed in 5.4.1. | ||||
| CVE-2025-3621 | 2026-04-15 | 9.6 Critical | ||
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems. * vulnerabilities: * Improper Neutralization of Special Elements used in a Command ('Command Injection') * Use of Hard-coded Credentials * Improper Authentication * Binding to an Unrestricted IP Address The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. | ||||
| CVE-2025-68130 | 1 Trpc | 1 Trpc | 2026-04-15 | N/A |
| tRPC allows users to build and consume fully typesafe APIs without schemas or code generation. Starting in version 10.27.0 and prior to versions 10.45.3 and 11.8.0, a A prototype pollution vulnerability exists in `@trpc/server`'s `formDataToObject` function, which is used by the Next.js App Router adapter. An attacker can pollute `Object.prototype` by submitting specially crafted FormData field names, potentially leading to authorization bypass, denial of service, or other security impacts. Note that this vulnerability is only present when using `experimental_caller` / `experimental_nextAppDirCaller`. Versions 10.45.3 and 11.8.0 fix the issue. | ||||
| CVE-2024-38989 | 1 Izatop | 1 Bunt | 2026-04-15 | 9.8 Critical |
| izatop bunt v0.29.19 was discovered to contain a prototype pollution via the component /esm/qs.js. This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties. | ||||
| CVE-2025-55164 | 1 Content-security-policy-parser Project | 1 Content-security-policy-parser | 2026-04-15 | N/A |
| content-security-policy-parser parses content security policy directives. A prototype pollution vulnerability exists in versions 0.5.0 and earlier, wherein if a policy name is called __proto__, one can override the Object prototype. This issue has been patched in version 0.6.0. A workaround involves disabling prototype method in NodeJS, neutralizing all possible prototype pollution attacks. Provide either --disable-proto=delete (recommended) or --disable-proto=throw as an argument to node to enable this feature. | ||||
| CVE-2024-36583 | 1 Byondreal | 1 Accessor | 2026-04-15 | 8.1 High |
| A Prototype Pollution issue in byondreal accessor <= 1.0.0 allows an attacker to execute arbitrary code via @byondreal/accessor/index. | ||||
| CVE-2024-38987 | 1 Ageoflearning | 1 Cli-lib | 2026-04-15 | 6.3 Medium |
| aofl cli-lib v3.14.0 was discovered to contain a prototype pollution via the component defaultsDeep. This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties. | ||||
| CVE-2024-52810 | 1 Intlify | 1 Vue-i18n | 2026-04-15 | N/A |
| @intlify/shared is a shared library for the intlify project. The latest version of @intlify/shared (10.0.4) is vulnerable to Prototype Pollution through the entry function(s) lib.deepCopy. An attacker can supply a payload with Object.prototype setter to introduce or modify properties within the global prototype chain, causing denial of service (DoS) as the minimum consequence. Moreover, the consequences of this vulnerability can escalate to other injection-based attacks, depending on how the library integrates within the application. For instance, if the polluted property propagates to sensitive Node.js APIs (e.g., exec, eval), it could enable an attacker to execute arbitrary commands within the application's context. This issue has been addressed in versions 9.14.2, and 10.0.5. Users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||