| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability exists in ZKTeco WL20 due to hard-coded MQTT credentials and endpoints stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve the hard-coded MQTT credentials and endpoints from the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the MQTT broker and manipulate the communications of the targeted device. |
| NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05. |
| INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models. |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Aptos Wisal payroll accounting before 7.1.6 uses hardcoded credentials in the Windows client to fetch the complete list of usernames and passwords from the database server, using an unencrypted connection. This allows attackers in a machine-in-the-middle position read and write access to personally identifiable information (PII) and especially payroll data and the ability to impersonate legitimate users with respect to the audit log. |
| A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| The default password for the extended admin user mode in the application U9ExosAdmin.exe ("Kaba 9300 Administration") is hard-coded in multiple locations as well as documented in the locally stored user documentation. |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to hard-coded Root Access Credentials in system configuration of the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to obtain the stored root access credentials.
Successful exploitation of this vulnerability could allow the attacker to gain admin access to the targeted device. |
| Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |
| Use of Hard-Coded Credentials issue exists in MZK-DP300N version 1.07 and earlier, which may allow an attacker within the local network to log in to the affected device via Telnet and execute arbitrary commands. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. |