Export limit exceeded: 429022 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (5460 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-6870 | 1 Siemens | 1 Simatic Wincc Sm\@rtclient | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. | ||||
| CVE-2016-8355 | 1 Smiths-medical | 1 Cadd-solis Medication Safety Software | 2025-04-20 | N/A |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. | ||||
| CVE-2017-6872 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. | ||||
| CVE-2017-6873 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. | ||||
| CVE-2017-5162 | 1 Binom3 | 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware | 2025-04-20 | N/A |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. | ||||
| CVE-2017-16241 | 1 Amag | 6 En-1dbc, En-1dbc Firmware, En-2dbc and 3 more | 2025-04-20 | N/A |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. | ||||
| CVE-2017-10604 | 1 Juniper | 2 Junos, Srx | 2025-04-20 | N/A |
| When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series. | ||||
| CVE-2017-10804 | 1 Odoo | 1 Odoo | 2025-04-20 | N/A |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. | ||||
| CVE-2017-3819 | 1 Cisco | 2 Asr 5000 Series Software, Virtualized Packet Core | 2025-04-20 | N/A |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. | ||||
| CVE-2017-14350 | 1 Hp | 1 Application Performance Management | 2025-04-20 | N/A |
| A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution. | ||||
| CVE-2016-5410 | 2 Firewalld, Redhat | 6 Firewalld, Enterprise Linux, Enterprise Linux Desktop and 3 more | 2025-04-20 | N/A |
| firewalld.py in firewalld before 0.4.3.3 allows local users to bypass authentication and modify firewall configurations via the (1) addPassthrough, (2) removePassthrough, (3) addEntry, (4) removeEntry, or (5) setEntries D-Bus API method. | ||||
| CVE-2016-5053 | 1 Osram | 1 Lightify Home | 2025-04-20 | N/A |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000. | ||||
| CVE-2024-48950 | 1 Logpoint | 2 Logpoint, Siem | 2025-04-18 | 7.5 High |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. | ||||
| CVE-2022-1070 | 1 Aethon | 1 Tug Home Base Server | 2025-04-17 | 8.2 High |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. | ||||
| CVE-2021-26264 | 1 Emerson | 2 Deltav Distributed Control System, Deltav Workstation | 2025-04-17 | 6.1 Medium |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. | ||||
| CVE-2021-22640 | 1 Ovarro | 15 Tbox Lt2-530, Tbox Lt2-530 Firmware, Tbox Lt2-532 and 12 more | 2025-04-17 | 7.5 High |
| An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks. | ||||
| CVE-2024-2076 | 1 Codeastro | 1 House Rental Management System | 2025-04-16 | 5.3 Medium |
| A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392. | ||||
| CVE-2021-33008 | 1 Aveva | 1 System Platform | 2025-04-16 | 8.8 High |
| AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity. | ||||
| CVE-2022-41644 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. | ||||
| CVE-2021-33843 | 1 Fresenius-kabi | 2 Agilia Sp Mc Wifi, Agilia Sp Mc Wifi Firmware | 2025-04-16 | 5.3 Medium |
| Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings. | ||||