| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When sending invalid base64 SASL data, login process is disconnected from the auth server, causing all active authentication sessions to fail. Invalid BASE64 data can be used to DoS a vulnerable server to break concurrent logins. Install fixed version or disable concurrency in login processes (heavy perfomance penalty on large deployments). No publicly available exploits are known. |
| When cache is enabled, some passdb/userdb drivers incorrectly cache all users with same cache key, causing wrong cached information to be used for these users. After cached login, all subsequent logins are for same user. Install fixed version or disable caching either globally or for the impacted passdb/userdb drivers. No publicly available exploits are known. |
| A Use of Hard-coded, Security-relevant Constants vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts. |
| Path Traversal vulnerability in NEC Platforms, Ltd. Aterm Series allows a attacker to wtite over any file via network. |
| Missing Authorization vulnerability in NEC Platforms, Ltd. Aterm Series allows a attacker to get a specific device information and change the settings via network. |
| A security flaw has been discovered in code-projects Online Food Ordering System 1.0. Affected by this issue is some unknown functionality of the file /dbfood/food.php. The manipulation of the argument cuisines results in cross site scripting. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. |
| A vulnerability was found in Tenda AC5 15.03.06.47. Impacted is the function formWifiWpsOOB of the file /goform/WifiWpsOOB of the component POST Request Handler. Performing a manipulation of the argument index results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used. |
| A security vulnerability has been detected in Shenzhen Ruiming Technology Streamax Crocus bis 1.3.44. Affected is an unknown function of the file /RemoteFormat.do of the component Endpoint. Such manipulation of the argument State leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A flaw was found in firewalld. A local unprivileged user can exploit this vulnerability by mis-authorizing two runtime D-Bus (Desktop Bus) setters, setZoneSettings2 and setPolicySettings. This mis-authorization allows the user to modify the runtime firewall state without proper authentication, leading to unauthorized changes in network security configurations. |
| Local File Inclusion in Contact Plan, E-Mail, SMS and Fax components in Asseco SEE Live 2.0 allows remote authenticated users to access files on the host via "path" parameter in the downloadAttachment and downloadAttachmentFromPath API calls. |
| A vulnerability allowing a low-privileged user to extract saved SSH credentials. |
| A vulnerability allowing an authenticated domain user to perform remote code execution (RCE) on the Backup Server. |
| A vulnerability allowing an authenticated domain user to bypass restrictions and manipulate arbitrary files on a Backup Repository. |
| A vulnerability allowing local privilege escalation on Windows-based Veeam Backup & Replication servers. |
| A vulnerability allowing a Backup Viewer to perform remote code execution (RCE) as the postgres user. |
| AI command injection in M365 Copilot allows an unauthorized attacker to disclose information over a network. |
| Improper export of android application components in Samsung Assistant prior to version 9.3.10.7 allows local attacker to access saved information. |
| URL redirection in Samsung Account prior to version 15.5.01.1 allows remote attackers to potentially get access token. |
| Exposure of sensitive functionality to an unauthorized actor in Smart Switch prior to version 3.7.69.15 allows remote attackers to set a specific configuration. |
| Use of a broken or risky cryptographic algorithm in Smart Switch prior to version 3.7.69.15 allows remote attackers to configure a downgraded scheme for authentication. |