Search Results (167 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-73454 1 Arista 1 Eos 2026-09-18 8.1 High
On affected platforms running Arista EOS with gRPC Network Security Interface (gNSI) Credentialz configured, a specially crafted request can cause unintended modifications to the target account's properties. This may result in the account being assigned elevated privileges or access beyond what an administrator intended.
CVE-2026-73464 1 Arista 1 Eos 2026-09-18 8.8 High
On affected platforms running Arista EOS with gRPC Network Management Interface (gNMI) enabled, a specially crafted request could allow a malicious authenticated client with gRPC Network Management Interface (gNMI) access to execute arbitrary code with root privileges on the switch.
CVE-2026-2380 1 Arista 1 Eos 2026-09-18 7.4 High
On affected platforms running Arista EOS with OpenConfig-related services (i.e., gNMI, gNSI, RESTCONF and NETCONF), sensitive requests and responses may be unintentionally logged. These may be stored on the local EOS device or recorded on remote accounting servers. Note that gRPC-based streaming via Streaming Telemetry Agent to CloudVision is not affected by this vulnerability. Examples of sensitive information include: - Sensitive CLI commands (e.g., "username bob secret myPass") - Sensitive OpenConfig YANG leafs (e.g., "system/aaa/global/tacacs/config/secret-key") This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
CVE-2026-73463 1 Arista 1 Eos 2026-09-18 5.3 Medium
On affected platforms running Arista EOS, when multiple gRPC Network Security Interface (gNSI) transports are configured, a race condition in the gNSI Authz service may cause a policy rotation to fail silently. An authenticated user whose access was revoked by the new policy may retain unauthorized access to gRPC interfaces. This does not affect Bootz. This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
CVE-2026-73438 1 Arista 1 Eos 2026-09-18 5.3 Medium
On affected platforms running Arista EOS with Open Shortest Path First version 3 (OSPFv3) configured, an unauthenticated attacker on the same OSPFv3 broadcast domain can send a specially crafted set of packets that can cause the Ospf3 agent to restart unexpectedly. The crash results in the loss of all OSPFv3 adjacencies on the affected device and may disrupt routing across the broader OSPF domain until the agent recovers. This issue was reported externally by Dravanet Inc., and Arista is not aware of any malicious exploitation of this vulnerability in customer networks.
CVE-2026-73455 1 Arista 1 Eos 2026-09-18 7.5 High
On affected platforms running Arista EOS with Open Shortest Path First version 3 (OSPFv3) configured, a specially crafted packet can cause the OSPFv3 agent to restart unexpectedly.
CVE-2026-73453 1 Arista 1 Eos 2026-09-18 10 Critical
An unauthenticated P4Runtime (Programming Protocol-Independent Packet Processors Runtime) client can achieve arbitrary code execution under certain conditions on affected platforms running Arista EOS configured with P4Runtime. P4Runtime is disabled by default in Arista EOS. By crafting a malicious packet during the initiation of a P4Runtime session, an attacker can obtain complete administrative control over the compromised switch. This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
CVE-2026-73440 1 Arista 1 Eos 2026-09-18 4.2 Medium
On affected platforms running Arista EOS with Simple Network Management Protocol (SNMP) configured, SNMPv3 local or remote user credentials may be exposed as a one-way hashed, localized key value within the device's running and sanitized configurations. An authenticated user who gains access to this sensitive information could leverage it to perform unauthorized read operations on SNMP tables or to send fraudulent trap notifications to the Network Management System (NMS). This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
CVE-2026-73456 1 Arista 1 Eos 2026-09-18 10 Critical
Under certain circumstances on affected platforms running Arista EOS with gRPC Network Packet Sampling Interface (gNPSI) enabled, an unauthenticated gNPSI client can craft a malicious request to allow arbitrary code execution, granting an attacker full administrative control over the compromised switch.
CVE-2026-73457 1 Arista 1 Eos 2026-09-18 5.3 Medium
Under certain circumstances on affected platforms running Arista EOS with gRPC Network Packet Sampling Interface (gNPSI) enabled, the gNPSI client credentials might be logged in clear text in local or remote accounting logs to authenticated users.
CVE-2026-73445 1 Arista 1 Eos 2026-09-17 4.9 Medium
On affected platforms running Arista EOS, an issue with the gRPC Network Security Interface (gNSI) Authz Rotate RPC may cause an incorrect Authz policy which was uploaded in the ongoing RPC stream to become active. This does not affect Bootz. This issue was discovered internally by Arista and the company is not aware of any malicious uses of this issue in customer networks.
CVE-2026-19640 1 Arista 1 Eos 2026-09-17 4.2 Medium
On affected platforms running Arista EOS, an authenticated user with access to the gNMI (gRPC Network Management Interface) may receive incorrect authorization results, potentially allowing access beyond their currently assigned permissions. This issue was discovered internally by Arista and the company is not aware of any malicious uses of this issue in customer networks.
CVE-2026-73435 1 Arista 1 Eos 2026-09-17 8.2 High
On affected platforms running Arista EOS with Open Shortest Path First version 2 (OSPFv2) configured, a specially crafted OSPFv2 packet from an unauthenticated attacker on the same broadcast segment, with OSPFv2 authentication configured can cause adjacency flapping and packet loss. The disruption can affect routing across the broader OSPF domain.
CVE-2026-73436 1 Arista 1 Eos 2026-09-17 6.5 Medium
On affected platforms running Arista EOS with OSPFv2 and OSPFv2 segment routing configured, a specially crafted OSPFv2 packet from an adjacent OSPF neighbor may cause OSPF to restart unexpectedly.
CVE-2026-73469 1 Arista 1 Eos 2026-09-17 5.8 Medium
When specific platforms are using Arista EOS with a loose Unicast Reverse Path Forwarding (uRPF) configuration, certain traffic may not be subjected to the intended verification drop. Consequently, traffic that should be dropped based on these routes could still be processed and forwarded by the device. This issue was discovered internally by Arista and the company is not aware of any malicious uses of this issue in customer networks.
CVE-2026-73468 1 Arista 1 Eos 2026-09-17 6.5 Medium
A specially crafted packet can cause the premature expiry of multicast forwarding state on affected interfaces, potentially resulting in temporary multicast traffic loss during the affected period.
CVE-2026-77190 1 Arista 1 Eos 2026-09-17 6.5 Medium
On affected platforms running Arista EOS, an unauthenticated attacker who is network-adjacent to the switch and able to connect to a device with PIM Sparse Mode and MLAG configured, can send malformed messages that cause the Pimsm agent to terminate unexpectedly. The Pimsm agent is automatically restarted, but repeated attacks can cause the agent to restart continuously, resulting in a sustained denial of service.
CVE-2026-86107 1 Arista 2 Velocloud, Velocloud Gateway 2026-09-17 5.9 Medium
The VeloCloud Edge and Gateway exhibit an out-of-bounds write vulnerability when processing tunneled IP fragments between authenticated overlay neighbors. This vulnerability impacts the VeloCloud VCMP tunnel protocol only. A successful exploit can cause the affected process to terminate and restart, leading to a temporary disruption of traffic. Hosts on the internet that are unauthenticated and unable to form an overlay peer relationship can not trigger the vulnerable logic.
CVE-2026-86106 1 Arista 1 Velocloud Edge 2026-09-17 9.6 Critical
An unauthenticated actor with network access to the private HA interconnect may trigger sensitive HA peer functions without verification. This could result in elevated command execution on Edge units where HA is enabled.
CVE-2026-31431 10 Amazon, Arista, Canonical and 7 more 60 Amazon Linux, Cloudvision Agni, Cloudvision Portal and 57 more 2026-09-08 7.8 High
In the Linux kernel, the following vulnerability has been resolved: crypto: algif_aead - Revert to operating out-of-place This mostly reverts commit 72548b093ee3 except for the copying of the associated data. There is no benefit in operating in-place in algif_aead since the source and destination come from different mappings. Get rid of all the complexity added for in-place operation and just copy the AD directly.