| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. |
| GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels. |
| GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information. |
| GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10. |
| GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user. |
| GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. |
| GE Gas Power ToolBoxST Version v04.07.05C suffers from an XML external entity (XXE) vulnerability using the DTD parameter entities technique that could result in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project/template file. |
| A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings. |
| A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host. |
| General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors. |
| Absolute path traversal vulnerability in the download feature in FileDownloadServlet in GE Digital Energy MDS PulseNET and MDS PulseNET Enterprise before 3.1.5 allows remote attackers to read or delete arbitrary files via a full pathname. |
| Buffer overflow in the Field Device Tool (FDT) Frame application in the HART Device Type Manager (DTM) library, as used in MACTek Bullet DTM 1.00.0, GE Vector DTM 1.00.0, GE SVi1000 Positioner DTM 1.00.0, GE SVI II AP Positioner DTM 2.00.1, and GE 12400 Level Transmitter DTM 1.00.0, allows remote attackers to cause a denial of service (DTM outage) via crafted packets. |
| GE Digital Energy MDS PulseNET and MDS PulseNET Enterprise before 3.1.5 have hardcoded credentials for a support account, which allows remote attackers to obtain administrative access, and consequently execute arbitrary code, by leveraging knowledge of the password. |
| General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors. |
| General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to obtain sensitive cleartext account information via unspecified vectors. |
| General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors. |
| General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface. |
| Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0. |
| Certain General Electric Renewable Energy products store cleartext credentials in flash memory. This affects iNET and iNET II before 8.3.0. |