| When calling base64.b64decode() or related functions the decoding process would stop after encountering the first padded quad regardless of whether there was more information to be processed. This can lead to data being accepted which may be processed differently by other implementations. Use "validate=True" to enable stricter processing of base64 data. |
| An issue in FinalWire AIRDA Extreme, AIDA64 Engineer, AIDA64 Business, AIDA64 Network Audit v.7.00.6700 and before allows a local attacker to escalate privileges via the DeviceIoControl call associated with MmMapIoSpace, IoAllocateMdl, MmBuildMdlForNonPagedPool, or MmMapLockedPages components. |
| A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian, caused by improper input validation in certain fields used in the Radius parsing functionality of our IDS, allows an unauthenticated attacker sending specially crafted malformed network packets to cause the IDS module to stop updating nodes, links, and assets.
Network traffic may not be analyzed until the IDS module is restarted. |
| The porte_plume plugin used by SPIP before 4.30-alpha2, 4.2.13, and 4.1.16 is vulnerable to an arbitrary code execution vulnerability. A remote and unauthenticated attacker can execute arbitrary PHP as the SPIP user by sending a crafted HTTP request. |
| util/JSONTokener.java in JSON-lib before 3.1.0 mishandles an unbalanced comment string. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the network configuration file via a crafted HTTP request. |
| 51l3nc3, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API managedoverlayimages.cgi was vulnerable to a race condition attack allowing for an attacker to block access to the overlay configuration page in the web interface of the Axis device. This flaw can only be exploited after authenticating with an operator- or administrator-privileged service account. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| Malformed BRID/HHIT records can cause `named` to terminate unexpectedly.
This issue affects BIND 9 versions 9.18.40 through 9.18.43, 9.20.13 through 9.20.17, 9.21.12 through 9.21.16, 9.18.40-S1 through 9.18.43-S1, and 9.20.13-S1 through 9.20.17-S1. |
| A vulnerability in the “Hosts” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the “hosts” file in an unintended manner via a crafted HTTP request. |
| A vulnerability in the “Proxy” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to manipulate the “/etc/environment” file via a crafted HTTP request. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the wireless network configuration file via a crafted HTTP request. |
| A low privileged remote attacker can corrupt the webserver users storage on the device by setting a sequence of unsupported characters which leads to deletion of all previously configured users and the creation of the default Administrator with a known default password. |
| 51l3nc3, member of the AXIS OS Bug Bounty Program, has found that a Guard Tour VAPIX API parameter allowed the use of arbitrary values allowing for an attacker to block access to the guard tour configuration page in the web interface of the Axis device.
Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| An Improper Input Validation vulnerability affecting the FTP service running on the DJI Mavic Mini 3 Pro could allow an attacker to craft a malicious packet containing a malformed path provided to the FTP SIZE command that leads to a denial-of-service attack of the FTP service itself. |
| An infinite loop issue in Amazon.IonDotnet library versions <v1.3.2 may allow a threat actor to cause a denial of service through a specially crafted text input.
To mitigate this issue, users should upgrade to version v1.3.2. As of August 20, 2025, this library has been deprecated and will not receive further updates. |
| An unauthenticated attacker who can connect to TCP port 9100 can issue a Printer Job Language (PJL) command that will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. A malformed PJL variable FORMLINES is set to a non number value causing the target to crash. |
| An unauthenticated attacker who can connect to the Web Services feature (HTTP TCP port 80) can issue a WS-Scan SOAP request containing an unexpected JobToken value which will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. |
| Denial of service due to improper handling of malformed input. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 40077, Acronis Cyber Protect 17 (Linux, macOS, Windows) before build 41186. |
| Westermo WeOS 5 through 5.23.0 allows a reboot via a malformed ESP packet. |
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |