| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in Tormach xsTECH CNC Router, PathPilot Controller v2.9.6 allows attackers to overwrite the hardcoded IP address in the device memory, disrupting network connectivity between the router and the controller. |
| A vulnerability, which was classified as problematic, has been found in elunez eladmin up to 2.7. Affected by this issue is some unknown functionality of the file eladmin-system\src\main\resources\config\application-prod.yml of the component Druid. The manipulation of the argument login-username/login-password leads to use of default credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases. |
| A vulnerability was determined in linlinjava litemall up to 1.8.0. Affected by this issue is some unknown functionality of the file litemall-wx-api/src/main/java/org/linlinjava/litemall/wx/util/JwtHelper.java of the component JSON Web Token Handler. The manipulation of the argument SECRET with the input X-Litemall-Token leads to hard-coded credentials. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. |
| A vulnerability was identified in Cudy LT500E up to 2.3.12. Affected is an unknown function of the file /squashfs-root/etc/shadow of the component Web Interface. The manipulation leads to use of hard-coded password. The attack must be carried out locally. The attack's complexity is rated as high. The exploitability is told to be difficult. The exploit is publicly available and might be used. Upgrading to version 2.3.13 is able to address this issue. It is recommended to upgrade the affected component. The vendor explains: "[T]he firmware does store a default password of 'admin'. This password has been deprecated since LT500E firmware version 2.3.13 and is no longer used. The LT500E does not have an administrator password set by default; a new password (at least 8 characters ) must be manually created upon first login the web management page." |
| A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized. |
| A security vulnerability has been detected in Tenda W12 up to 3.0.0.6(3948). Affected is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. The manipulation leads to hard-coded credentials. An attack has to be approached locally. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. |
| An issue was discovered in UCI IDOL 2 (aka uciIDOL or IDOL2) through 2.12. Data is sent between client and server with encryption. However, the key is derived from the string "(c)2007 UCI Software GmbH B.Boll" (without quotes). The key is both static and hardcoded. With access to messages, this results in message decryption and encryption by an attacker. Thus, it enables passive and active man-in-the-middle attacks. |
| Log files uploaded during troubleshooting by the Harmony SASE agent may have been accessible to unauthorized parties. |
| The default credentials for the setup HSQL database (HSQLDB) for FileCatalyst Workflow are published in a vendor knowledgebase article. Misuse of these credentials could lead to a compromise of confidentiality, integrity, or availability of the software.
The HSQLDB is only included to facilitate installation, has been deprecated, and is not intended for production use per vendor guides. However, users who have not configured FileCatalyst Workflow to use an alternative database per recommendations are vulnerable to attack from any source that can reach the HSQLDB. |
| The Admin and Site Enhancements (ASE) WordPress plugin before 7.6.10 uses a hardcoded password in its Password Protection feature, allowing attacker to bypass the protection offered via a crafted request |
| A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used. |
| IBM Concert Software 1.0.0 through 1.1.0
contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| A security flaw has been discovered in Tenda AC20 16.03.08.12. Affected by this vulnerability is an unknown functionality of the file /etc_ro/shadow. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device
locally or over the network. |
| IBM Cognos Controller 11.0.0 through 11.0.1 FP3 and IBM Controller 11.1.0 client application contains hard coded database passwords in source code which could be used for unauthorized access to the system. |
| WOLFBOX Level 2 EV Charger Management Card Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows physically present attackers to bypass authentication on affected installations of WOLFBOX Level 2 EV Charger. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of management cards. The issue results from the lack of personalization of management cards. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26292. |
| Softing Secure Integration Server Hardcoded Cryptographic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within libopcuaclient.so. The issue results from hardcoding crytographic keys within the product. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-20610. |
| Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device. |