| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In approvalLevelForDomainInternal of DomainVerificationService.java, there is a possible way to hijack an arbitrary app link due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| It was discovered that dpkg-deb (a component of dpkg, the Debian package management system) does not properly validate the end of the data stream when uncompressing a zstd-compressed .deb archive, which may result in denial of service (infinite loop spinning the CPU). |
| dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors. |
| Claude HUD through 0.0.12, patched in commit 234d9aa, contains a path traversal vulnerability that allows attackers to read arbitrary files by supplying an unvalidated transcript_path value via stdin JSON. Attackers can access any file readable by the process and the file metadata is written to a persistent cache file with insufficient permissions, creating a forensic record of accessed paths that survives process exit. |
| Claude HUD through 0.0.12, patched in commit 234d9aa, constructs OSC 8 terminal hyperlink escape sequences using raw cwd and branchUrl values without stripping control characters or encoding embedded values, allowing attackers to inject arbitrary ANSI codes into terminal sessions. Attackers can embed ESC+backslash sequences in the current working directory or branch URL to execute malicious ANSI codes including text color changes, forged prompts, and OSC 52 clipboard writes, or trigger outbound HTTP requests to attacker-controlled remotes when hyperlinks are clicked. |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. |
| Claude HUD through 0.0.12, patched in commit 234d9aa, contains a command injection vulnerability that allows local attackers to execute arbitrary commands by manipulating the COMSPEC environment variable. Attackers can set COMSPEC to an arbitrary binary path before claude-hud performs its version check, causing execFile() to execute the attacker-supplied executable with cmd.exe arguments, resulting in arbitrary code execution on Windows systems. |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. |
| Local File Inclusion in Contact Plan, E-Mail, SMS and Fax components in Asseco SEE Live 2.0 allows remote authenticated users to access files on the host via "path" parameter in the downloadAttachment and downloadAttachmentFromPath API calls. |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. |
| The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a cross-site origin WebSocket hijacking attack. Among other uses, the WDU utilizes WebSockets to control settings, including administrative settings. This allows a network attacker to take full control of a WDU. To initiate an exploit of this vulnerability, the victim must (1) be utilizing a web browser on a multihomed host that has local interfaces on the Garmin Marine Network as well as another network, and (2) access a malicious third party website created by the attacker. |
| The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a reflected cross site scripting (XSS) attack. This allows an attacker on the local network segment to execute arbitrary JavaScript code within the context of the WDU webpage. Full administrator level access to the device is possible. To initiate an exploit of this vulnerability, the victim must execute two actions: (1) view a specific URL served by the WDU, and (2) click an element on the rendered page. |
| A flaw was found in 389-ds-base. The get_ldapmessage_controls_ext() function in the LDAP server does not enforce an upper bound on the number of controls per LDAP message. A remote, unauthenticated attacker can send a specially crafted LDAP request containing hundreds of thousands of minimal controls within the default maximum BER message size (2 MB), causing excessive CPU consumption and heap allocation on the server. Under concurrent exploitation, this leads to significant latency degradation, worker thread starvation, or out-of-memory termination, resulting in a denial of service. |
| A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. |
| NVIDIA NVTabular contains a vulnerability where an attacker could cause improper deserialization of untrusted data. A successful exploit of this vulnerability might lead to code execution, data tampering, and information disclosure. |
| In performPreInstallChecks of InstallRepository.kt, there is a possible way to bypass MDM policy due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| In isSameApp of NotificationManagerService.java, there is a possible persistent dos due to resource exhaustion. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation. |
| Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/13/26UDPVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q12DCCPU-V all versions, Mitsubishi Electric MELSEC-Q Series Q24DHCCPU-V(G) all versions, Mitsubishi Electric MELSEC-Q Series Q24/26DHCCPU-LS all versions, Mitsubishi Electric MELSEC-L series L02/06/26CPU(-P) the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-L series L26CPU-(P)BT the first 5 digits of serial number "24051" and prior and Mitsubishi Electric MELIPC Series MI5122-VW firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition in Ethernet communications by sending specially crafted packets. A system reset of the products is required for recovery. |
| In multiple functions of PipTaskOrganizer.java, there is a possible way to launch an activity from the background due to a confused deputy. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| In setUserDisclaimerAcknowledged of CarDevicePolicyService.java, there is a possible way to bypass the user dialog when adding an account to a managed device due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |