Search

Search Results (355060 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-2376 2 Mirror-registry, Redhat 4 Quay, Enterprise Linux, Mirror Registry and 1 more 2026-06-02 4.9 Medium
A flaw was found in mirror-registry where an authenticated user can trick the system into accessing unintended internal or restricted systems by providing malicious web addresses. When the application processes these addresses, it automatically follows redirects without verifying the final destination, allowing attackers to route requests to systems they should not have access to.
CVE-2026-42791 1 Erlang 3 Erlang/otp, Erlang\/otp, Otp 2026-06-02 3.7 Low
Improper Certificate Validation vulnerability in Erlang OTP public_key (pubkey_ocsp module) allows forged OCSP responses signed with an expired responder certificate to be accepted as valid. OCSP response verification in pubkey_ocsp:verify_response/5 and pubkey_ocsp:is_authorized_responder/3 in lib/public_key/src/pubkey_ocsp.erl does not check the validity period (notBefore/notAfter) of the OCSP responder certificate. An attacker who has obtained the private key of an expired CA-designated OCSP responder certificate can forge OCSP responses that Erlang/OTP accepts as valid. This affects TLS clients using OCSP stapling via the ssl application: a malicious or compromised server can present a revoked TLS certificate together with a forged OCSP response signed by an expired responder key, and the client will accept the revoked certificate as valid. It also affects applications calling public_key:pkix_ocsp_validate/5 directly, where the impact depends on the use case — server-side client certificate validation using this API may allow authentication bypass with a revoked client certificate. This issue affects OTP from OTP 27.0 before OTP 27.3.4.12, 28.5.0.1, and 29.0.1 corresponding to public_key from 1.16 before 1.17.1.3, 1.20.3.1, and 1.21.1.
CVE-2026-0087 1 Google 1 Android 2026-06-02 7.8 High
In approvalLevelForDomainInternal of DomainVerificationService.java, there is a possible way to hijack an arbitrary app link due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
CVE-2026-2219 1 Debian 1 Dpkg 2026-06-02 7.5 High
It was discovered that dpkg-deb (a component of dpkg, the Debian package management system) does not properly validate the end of the data stream when uncompressing a zstd-compressed .deb archive, which may result in denial of service (infinite loop spinning the CPU).
CVE-2013-4734 2 Digital Alert Systems, Monroe Electronics 2 Dasdec Eas, R189 One-net Eas 2026-06-02 7.3 High
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
CVE-2026-47091 1 Jarrodwatts 2 Claude-hud, Claude Hud 2026-06-02 3.3 Low
Claude HUD through 0.0.12, patched in commit 234d9aa, contains a path traversal vulnerability that allows attackers to read arbitrary files by supplying an unvalidated transcript_path value via stdin JSON. Attackers can access any file readable by the process and the file metadata is written to a persistent cache file with insufficient permissions, creating a forensic record of accessed paths that survives process exit.
CVE-2026-47090 1 Jarrodwatts 2 Claude-hud, Claude Hud 2026-06-02 4.6 Medium
Claude HUD through 0.0.12, patched in commit 234d9aa, constructs OSC 8 terminal hyperlink escape sequences using raw cwd and branchUrl values without stripping control characters or encoding embedded values, allowing attackers to inject arbitrary ANSI codes into terminal sessions. Attackers can embed ESC+backslash sequences in the current working directory or branch URL to execute malicious ANSI codes including text color changes, forged prompts, and OSC 52 clipboard writes, or trigger outbound HTTP requests to attacker-controlled remotes when hyperlinks are clicked.
CVE-2021-27384 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
CVE-2026-47092 1 Jarrodwatts 2 Claude-hud, Claude Hud 2026-06-02 7.8 High
Claude HUD through 0.0.12, patched in commit 234d9aa, contains a command injection vulnerability that allows local attackers to execute arbitrary commands by manipulating the COMSPEC environment variable. Attackers can set COMSPEC to an arbitrary binary path before claude-hud performs its version check, causing execFile() to execute the attacker-supplied executable with cmd.exe arguments, resulting in arbitrary code execution on Windows systems.
CVE-2021-27385 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2026-06-02 7.5 High
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
CVE-2025-66955 1 Asseco 2 Live, See Live 2026-06-02 6.5 Medium
Local File Inclusion in Contact Plan, E-Mail, SMS and Fax components in Asseco SEE Live 2.0 allows remote authenticated users to access files on the host via "path" parameter in the downloadAttachment and downloadAttachmentFromPath API calls.
CVE-2021-27386 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2026-06-02 7.5 High
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
CVE-2025-27851 1 Garmin 3 Empirbus Wireless Display Unit, Empirbus Wireless Display Unit Firmware, Wdu 2026-06-02 9.3 Critical
The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a cross-site origin WebSocket hijacking attack. Among other uses, the WDU utilizes WebSockets to control settings, including administrative settings. This allows a network attacker to take full control of a WDU. To initiate an exploit of this vulnerability, the victim must (1) be utilizing a web browser on a multihomed host that has local interfaces on the Garmin Marine Network as well as another network, and (2) access a malicious third party website created by the attacker.
CVE-2025-27852 1 Garmin 3 Empirbus Wireless Display Unit, Empirbus Wireless Display Unit Firmware, Wdu 2026-06-02 5 Medium
The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a reflected cross site scripting (XSS) attack. This allows an attacker on the local network segment to execute arbitrary JavaScript code within the context of the WDU webpage. Full administrator level access to the device is possible. To initiate an exploit of this vulnerability, the victim must execute two actions: (1) view a specific URL served by the WDU, and (2) click an element on the rendered page.
CVE-2026-9064 1 Redhat 4 389 Directory Server, Directory Server, Enterprise Linux and 1 more 2026-06-02 7.5 High
A flaw was found in 389-ds-base. The get_ldapmessage_controls_ext() function in the LDAP server does not enforce an upper bound on the number of controls per LDAP message. A remote, unauthenticated attacker can send a specially crafted LDAP request containing hundreds of thousands of minimal controls within the default maximum BER message size (2 MB), causing excessive CPU consumption and heap allocation on the server. Under concurrent exploitation, this leads to significant latency degradation, worker thread starvation, or out-of-memory termination, resulting in a denial of service.
CVE-2020-15786 1 Siemens 8 Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Basic Panels 2nd Generation Firmware, Simatic Hmi Comfort Panels and 5 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
CVE-2026-24237 1 Nvidia 1 Nvtabular 2026-06-02 7.8 High
NVIDIA NVTabular contains a vulnerability where an attacker could cause improper deserialization of untrusted data. A successful exploit of this vulnerability might lead to code execution, data tampering, and information disclosure.
CVE-2025-48652 1 Google 1 Android 2026-06-02 7.8 High
In performPreInstallChecks of InstallRepository.kt, there is a possible way to bypass MDM policy due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
CVE-2025-48648 1 Google 1 Android 2026-06-02 5.5 Medium
In isSameApp of NotificationManagerService.java, there is a possible persistent dos due to resource exhaustion. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation.
CVE-2022-24946 1 Mitsubishielectric 64 L02cpu, L02cpu-p, L02cpu-p Firmware and 61 more 2026-06-02 7.5 High
Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/13/26UDPVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q12DCCPU-V all versions, Mitsubishi Electric MELSEC-Q Series Q24DHCCPU-V(G) all versions, Mitsubishi Electric MELSEC-Q Series Q24/26DHCCPU-LS all versions, Mitsubishi Electric MELSEC-L series L02/06/26CPU(-P) the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-L series L26CPU-(P)BT the first 5 digits of serial number "24051" and prior and Mitsubishi Electric MELIPC Series MI5122-VW firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition in Ethernet communications by sending specially crafted packets. A system reset of the products is required for recovery.