| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Passing a heavily nested list to sqlparse.parse() leads to a Denial of Service due to RecursionError.
|
| An authorization bypass through user-controlled key vulnerability affecting 3DSwym in 3DSwymer on Release 3DEXPERIENCE R2024x allows an authenticated attacker to access some unauthorized data. |
| Certain motherboard models developed by ASRock and its subsidiaries, ASRockRack and ASRockInd. has a Protection Mechanism Failure vulnerability. Because IOMMU was not properly enabled, unauthenticated physical attackers can use a DMA-capable PCIe device to read and write arbitrary physical memory before the OS kernel and its security features are loaded. |
| Certain motherboard models developed by MSI has a Protection Mechanism Failure vulnerability. Because IOMMU was not properly enabled, unauthenticated physical attackers can use a DMA-capable PCIe device to read and write arbitrary physical memory before the OS kernel and its security features are loaded. |
| Certain motherboard models developed by GIGABYTE has a Protection Mechanism Failure vulnerability. Because IOMMU was not properly enabled, unauthenticated physical attackers can use a DMA-capable PCIe device to read and write arbitrary physical memory before the OS kernel and its security features are loaded. |
| A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.
Other related CVE's are CVE-2025-14096 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required configuration for Exposure:
Physical access to the analyzer is needed.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note:
CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems. |
| In OceanBase's Oracle tenant mode, a malicious user with specific privileges can achieve privilege escalation to SYS-level access by executing carefully crafted commands.
This vulnerability only affects OceanBase tenants in Oracle mode. Tenants in MySQL mode are unaffected. |
| A vulnerability has been found in Union Bank of India Vyom 8.0.34 on Android and classified as problematic. This vulnerability affects unknown code of the component Rooting Detection. The manipulation leads to protection mechanism failure. The attack needs to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends updating to the most recent version of this product, service or offering (S35 Pinhole/Kit Camera to version 2025.08.28, S35 AI Fisheye & Dual Sensor/Micro Dome/Full Color Eyeball & Bullet Camera to version 2025.08.22, S35 Thermal Camera to version 2025.08.26). |
| If a `named` caching resolver is configured with `serve-stale-enable` `yes`, and with `stale-answer-client-timeout` set to `0` (the only allowable value other than `disabled`), and if the resolver, in the process of resolving a query, encounters a CNAME chain involving a specific combination of cached or authoritative records, the daemon will abort with an assertion failure.
This issue affects BIND 9 versions 9.20.0 through 9.20.10, 9.21.0 through 9.21.9, and 9.20.9-S1 through 9.20.10-S1. |
| An authentication bypass vulnerability was reported in FileZ client application that could allow a local attacker with elevated permissions access to application data. |
| Improper synchronization in the firmware for some Intel(R) TDX may allow a privileged user to potentially enable escalation of privilege via local access. |
| The overly permissive sandbox configuration in DSPy allows attackers to steal sensitive files in cases when users build an AI agent which consumes user input and uses the “PythonInterpreter” class. |
| CWE-639 Authorization Bypass Through User-Controlled Key |
| Local privilege escalation due to improper soft link handling. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 40296. |
| Client queries that trigger serving stale data and that also require lookups in local authoritative zone data may result in an assertion failure.
This issue affects BIND 9 versions 9.16.13 through 9.16.50, 9.18.0 through 9.18.27, 9.19.0 through 9.19.24, 9.11.33-S1 through 9.11.37-S1, 9.16.13-S1 through 9.16.50-S1, and 9.18.11-S1 through 9.18.27-S1. |
| Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31 |
| Tronclass developed by WisdomGarden has an Insecure Direct object Reference vulnerability, allowing remote attackers with regular privilege to modify a specific parameter to access other users' files. |
| Authorization Bypass Through User-Controlled Key vulnerability in Propovoice Propovoice CRM.This issue affects Propovoice CRM: from n/a through 1.7.6.4. |
| Anubis is a Web AI Firewall Utility that challenges users' connections in order to protect upstream resources from scraper bots. Prior to version 1.23.0, when using subrequest authentication, Anubis did not perform validation of the redirect URL and redirects user to any URL scheme. While most modern browsers do not allow a redirect to `javascript:` URLs, it could still trigger dangerous behavior in some cases. Anybody with a subrequest authentication may be affected. Version 1.23.0 contains a fix for the issue. |