| The specific APIs of Parking Management System from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access specific APIs and operate system functions. These functions include opening gates and restarting the system. |
| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |
| An issue in Shelly com.home.shelly 1.0.4 allows a remote attacker to obtain sensitive information via the firmware update process |
| Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication. |
| Vulnerability in mojofywp WP Affiliate Disclosure wp-affiliate-disclosure.This issue affects WP Affiliate Disclosure: from n/a through 1.2.6. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| Entrust Instant Financial Issuance (IFI) On Premise software (formerly referred to as CardWizard) versions 5.x, prior to 6.10.5, and prior to 6.11.1 contain an insecure .NET Remoting exposure in the Legacy Remoting Service that is enabled by default. The service registers a TCP remoting channel with SOAP and binary formatters configured at TypeFilterLevel=Full and exposes default ObjectURI endpoints such as logfile.rem, photo.rem, cwPhoto.rem, and reports.rem on a network-reachable remoting port. A remote, unauthenticated attacker who can reach the remoting port can invoke exposed remoting objects to read arbitrary files from the server and coerce outbound authentication, and may achieve arbitrary file write and remote code execution via known .NET Remoting exploitation techniques. This can lead to disclosure of sensitive installation and service-account data and compromise of the affected host. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| A missing authentication vulnerability in Palo Alto Networks Cortex XDR® Broker VM allows an unauthenticated user to disable certain internal services on the Broker VM.
The attacker must have network access to the Broker VM to exploit this issue. |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| Incorrect access control in Shenzhen Tuoshi Network Communications Co.,Ltd 5G CPE Router NR500-EA RG500UEAABxCOMSLICv3.2.2543.12.18 allows attackers to access the SSH protocol without authentication. |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screen and gain limited access to the system. |
| An unauthenticated remote code execution vulnerability exists in Remote for Mac, a macOS remote control utility developed by Aexol Studio, in versions up to and including 2025.7. When the application is configured with authentication disabled (i.e., the "Allow unknown devices" option is enabled), the /api/executeScript endpoint is exposed without access control. This allows unauthenticated remote attackers to inject arbitrary AppleScript payloads via the X-Script HTTP header, resulting in code execution using do shell script. Successful exploitation grants attackers the ability to run arbitrary commands on the macOS host with the privileges of the Remote for Mac background process. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| Peppermint Ticket Management 0.4.6 is vulnerable to Incorrect Access Control. A regular registered user is able to elevate his privileges to admin and gain complete access to the system as the authorization mechanism is not validated on the server side and only on the client side. This can result, for example, in creating a new admin user in the system which enables persistent access for the attacker as an administrator. |
| SpaceX Starlink Dish devices with firmware 2024.12.04.mr46620 (e.g., on Mini1_prod2) allow administrative actions via unauthenticated LAN gRPC requests, aka MARMALADE 2. The cross-origin policy can be bypassed by omitting a Referer header. In some cases, an attacker's ability to read tilt, rotation, and elevation data via gRPC can make it easier to infer the geographical location of the dish. |