| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |
| A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp) |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| A unauthorized access vulnerability exists in the Xiaomi phone framework. The vulnerability is caused by improper validation and can be exploited by attackers to Access sensitive methods. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) versions prior to 1.3.4 contain an authentication bypass in the NVMS-9000 control protocol. By sending a single crafted TCP payload to an exposed NVMS-9000 control port, an unauthenticated remote attacker can invoke privileged administrative query commands without valid credentials. Successful exploitation discloses sensitive information including administrator usernames and passwords in cleartext, network and service configuration, and other device details via commands such as queryBasicCfg, queryUserList, queryEmailCfg, queryPPPoECfg, and queryFTPCfg. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| Reolink Video Doorbell WiFi DB_566128M5MP_W allows root shell access through an unsecured UART/serial console. An attacker with physical access can connect to the exposed interface and execute arbitrary commands with root privileges. NOTE: this is disputed by the Supplier because of "certain restrictions on users privately connecting serial port cables" and because "the root user has a password and it meets the requirements of password security complexity." |
| An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process. |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |
| An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function. |
| NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure. |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. |
| A remote code execution vulnerability exists in CryptoLog (PHP version, discontinued since 2009) due to a chained exploitation of SQL injection and command injection vulnerabilities. An unauthenticated attacker can gain shell access as the web server user by first exploiting a SQL injection flaw in login.php to bypass authentication, followed by command injection in logshares_ajax.php to execute arbitrary operating system commands.
The login bypass is achieved by submitting crafted SQL via the user POST parameter. Once authenticated, the attacker can abuse the lsid POST parameter in the logshares_ajax.php endpoint to inject and execute a command using $(...) syntax, resulting in code execution under the web context.
This exploitation path does not exist in the ASP.NET version of CryptoLog released since 2009. |
| Due to missing authentication, SAP HANA 2.0 (hdbrss) allows an unauthenticated attacker to call a remote-enabled function that will enable them to view information. As a result, it has a low impact on the confidentiality but no impact on the integrity and availability of the system. |