Search Results (79 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-2444 1 Rockwellautomation 1 Factorytalk Vantagepoint 2025-01-24 7.1 High
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.  Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.
CVE-2023-2639 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2025-01-02 4.1 Medium
The underlying feedback mechanism of Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device.  This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. 
CVE-2023-2638 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2025-01-02 5.9 Medium
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.   Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.  This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
CVE-2023-2637 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2025-01-02 7.3 High
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies.  Hard-coded cryptographic key may lead to privilege escalation.  This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.
CVE-2024-21915 1 Rockwellautomation 1 Factorytalk Services Platform 2024-12-11 9 Critical
A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.
CVE-2024-6326 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2024-11-21 5.5 Medium
An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network.
CVE-2024-6325 1 Rockwellautomation 1 Factorytalk Policy Manager 2024-11-21 6.5 Medium
The v6.40 release of Rockwell Automation FactoryTalk® Policy Manager CVE-2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html  and CVE-2022-1161 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html  by implementing CIP security and did not update to the versions of the software CVE-2022-1161 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html  and CVE-2022-1161. https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html
CVE-2024-37367 1 Rockwellautomation 1 Factorytalk View 2024-11-21 7.5 High
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
CVE-2024-21917 1 Rockwellautomation 1 Factorytalk Services Platform 2024-11-21 9.8 Critical
A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of digital signing between the FTSP service token and directory.  If exploited, a malicious user could potentially retrieve user information and modify settings without any authentication.
CVE-2023-2071 1 Rockwellautomation 2 Factorytalk View, Panelview Plus 2024-11-21 9.8 Critical
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
CVE-2023-29464 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 8.2 High
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CVE-2021-22681 1 Rockwellautomation 20 Compact Guardlogix 5370, Compact Guardlogix 5380, Compactlogix 1768 and 17 more 2024-11-21 9.8 Critical
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
CVE-2020-6967 1 Rockwellautomation 1 Factorytalk Services Platform 2024-11-21 9.8 Critical
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
CVE-2020-5807 1 Rockwellautomation 1 Factorytalk Diagnostics 2024-11-21 7.5 High
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
CVE-2020-5806 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 5.5 Medium
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
CVE-2020-5802 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 7.5 High
An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.
CVE-2020-5801 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 7.5 High
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
CVE-2020-27255 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 7.5 High
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).
CVE-2020-27253 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 7.5 High
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device.
CVE-2020-27251 1 Rockwellautomation 1 Factorytalk Linx 2024-11-21 9.8 Critical
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.