Search Results (812 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-31972 1 Hcltech 1 Bigfix Service Management 2025-10-29 6.5 Medium
HCL BigFix SM is affected by a Sensitive Information Exposure vulnerability where internal connections do not use TLS encryption which could allow an attacker unauthorized access to sensitive data transmitted between internal components.
CVE-2025-11640 2 Furbo, Tomofun 6 Furbo 360 Dog Camera, Furbo 360 Dog Camera Firmware, Furbo Mini and 3 more 2025-10-29 3.1 Low
A vulnerability was found in Tomofun Furbo 360 and Furbo Mini. This affects an unknown function of the component Bluetooth Low Energy. The manipulation results in cleartext transmission of sensitive information. Access to the local network is required for this attack. Attacks of this nature are highly complex. The exploitability is reported as difficult. The firmware versions determined to be affected are Furbo 360 up to FB0035_FW_036 and Furbo Mini up to MC0020_FW_074. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-59406 3 Flock Safety, Flocksafety, Google 7 Bravo Edge Ai Compute Device, Bravo Edge Ai Compute Device, Falcon and 4 more 2025-10-24 6.2 Medium
The Flock Safety Pisco com.flocksafety.android.pisco application 6.21.11 for Android (installed on Falcon and Sparrow License Plate Readers and Bravo Edge AI Compute Devices) has a cleartext Auth0 client secret in its codebase. Because application binaries can be trivially decompiled or inspected, attackers can recover this OAuth secret without special privileges. This secret is intended to remain confidential and should never be embedded directly in client-side software.
CVE-2025-56447 1 Tm2 1 Monitoring 2025-10-23 9.8 Critical
TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure.
CVE-2025-36020 1 Ibm 2 Guardium Data Protection, Security Guardium 2025-10-22 5.9 Medium
IBM Guardium Data Protection could allow a remote attacker to obtain sensitive information due to cleartext transmission of sensitive credential information.
CVE-2025-41718 1 Murrelektronik 4 Firmware Impact67 Pro 54620, Firmware Impact67 Pro 54630, Firmware Impact67 Pro 54631 and 1 more 2025-10-21 7.5 High
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
CVE-2025-55976 1 Intelbras 2 Iwr 3000n, Iwr 3000n Firmware 2025-10-17 8.4 High
Intelbras IWR 3000N 1.9.8 exposes the Wi-Fi password in plaintext via the /api/wireless endpoint. Any unauthenticated user on the local network can directly obtain the Wi-Fi network password by querying this endpoint.
CVE-2025-54156 1 Santesoft 1 Sante Pacs Server 2025-10-17 7.4 High
The Sante PACS Server Web Portal sends credential information without encryption.
CVE-2025-7743 1 Dolusoft 1 Omaspot 2025-10-15 9.6 Critical
Cleartext Transmission of Sensitive Information vulnerability in Dolusoft Omaspot allows Interception, Privilege Escalation.This issue affects Omaspot: before 12.09.2025.
CVE-2025-2861 1 Arteche 2 Satech Bcu, Satech Bcu Firmware 2025-10-10 7.5 High
SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately.
CVE-2024-25650 1 Delinea 2 Distributed Engine, Secret Server 2025-10-10 5.9 Medium
Insecure key exchange between Delinea PAM Secret Server 11.4 and the Distributed Engine 8.4.3 allows a PAM administrator to obtain the Symmetric Key (used to encrypt RabbitMQ messages) via crafted payloads to the /pre-authenticate, /authenticate, and /execute-and-respond REST API endpoints. This makes it possible for a PAM administrator to impersonate the Engine and exfiltrate sensitive information from the messages published in the RabbitMQ exchanges, without being audited in the application.
CVE-2025-0250 1 Hcltech 1 Intelliops Event Management 2025-10-09 2.2 Low
HCL IEM is affected by an authorization token sent in cookie vulnerability.  A token used for authentication and authorization is being handled in a manner that may increase its exposure to security risks.
CVE-2025-0252 1 Hcltech 1 Intelliops Event Management 2025-10-09 2.6 Low
HCL IEM is affected by a password in cleartext vulnerability.  Sensitive information is transmitted without adequate protection, potentially exposing it to unauthorized access during transit.
CVE-2024-41757 1 Ibm 1 Concert 2025-09-29 5.9 Medium
IBM Concert Software 1.0.0 and 1.0.1 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques.
CVE-2024-31905 1 Ibm 1 Qradar Network Packet Capture 2025-09-29 5.9 Medium
IBM QRadar Network Packet Capture 7.5 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques.
CVE-2017-20200 2025-09-24 3.7 Low
A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings."
CVE-2025-10776 1 Lioncoders 1 Salepro Pos 2025-09-22 3.7 Low
A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-47698 1 Cognex 1 In-sight Explorer 2025-09-19 N/A
An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.
CVE-2025-54818 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2025-09-19 8 High
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.
CVE-2024-0098 2 Microsoft, Nvidia 2 Windows, Chatrtx 2025-09-17 5.5 Medium
NVIDIA ChatRTX for Windows contains a vulnerability in the ChatRTX UI and backend, where a user can cause a clear-text transmission of sensitive information issue by data sniffing. A successful exploit of this vulnerability might lead to information disclosure.