| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the monitor services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 is vulnerable to cross-site scripting in its backup services. An attacker could take advantage of this vulnerability to execute arbitrary commands.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
|
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior are vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code or crash the device remotely.
|
| All versions of Landis+Gyr E850 (ZMQ200) are vulnerable to CWE-784: Reliance on Cookies Without Validation and Integrity. The device's web application navigation depends on the value of the session cookie. The web application could become inaccessible for the user if an attacker changes the cookie values.
|
| All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
|
|
Echelon SmartServer 2.2 with i.LON Vision 2.2 stores cleartext credentials in a file, which could allow an attacker to obtain cleartext usernames and passwords of the SmartServer. If the attacker obtains the file, then the credentials could be used to control the web user interface and file transfer protocol (FTP) server.
|
|
Control By Web X-400 devices are vulnerable to a cross-site scripting attack, which could result in private and session information being transferred to the attacker.
|
| If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
|
|
The Sub-IoT implementation of the DASH 7 Alliance protocol has a vulnerability that can lead to an out-of-bounds write prior to implementation version 0.5.0. If the protocol has been compiled using default settings, this will only grant the attacker access to allocated but unused memory. However, if it was configured using non-default settings, there is the possibility that exploiting this vulnerability could lead to system crashes and remote code execution.
|
| The Akuvox E11 web server backend library allows command injection in the device phone-book contacts functionality. This could allow an attacker to upload files with executable command instructions. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution. |
|
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.
|
| Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device. |
| Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script. |
| Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts. |