| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue has been discovered in GitLab CE/EE affecting all versions before 16.8.5, all versions starting from 16.9 before 16.9.3, all versions starting from 16.10 before 16.10.1. A wiki page with a crafted payload may lead to a Stored XSS, allowing attackers to perform arbitrary actions on behalf of victims. |
| An integer overflow can occur in NTP-dev.4.3.70 leading to an out-of-bounds memory copy operation when processing a specially crafted private mode packet. The crafted packet needs to have the correct message authentication code and a valid timestamp. When processed by the NTP daemon, it leads to an immediate crash. |
| Online Tours & Travels Management System v1.0 was discovered to contain a SQL injection vulnerability via the id parameter at /tour/admin/update_tax.php. |
| Online Tours & Travels Management System v1.0 was discovered to contain a SQL injection vulnerability via the id parameter at /tour/admin/update_payment.php. |
| Online Tours & Travels Management System v1.0 was discovered to contain a SQL injection vulnerability via the id parameter at /tour/admin/update_packages.php. |
| A local privilege escalation vulnerability in UI Desktop for Windows (Version 0.55.1.2 and earlier) allows a malicious actor with local access to a Windows device with UI Desktop to run arbitrary commands as SYSTEM. |
| Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/ |
| IBM Sterling Partner Engagement Manager 6.1 is vulnerable to an XML External Entity Injection (XXE) attack when processing XML data. A remote attacker could exploit this vulnerability to expose sensitive information or consume memory resources. IBM X-Force ID: 230017. |
| An out-of-bounds read issue was addressed with improved input validation. This issue is fixed in macOS Monterey 12.5. Processing a maliciously crafted AppleScript binary may result in unexpected termination or disclosure of process memory. |
| The issue was addressed with improved memory handling. This issue is fixed in iOS 15.6 and iPadOS 15.6, macOS Big Sur 11.6.8, watchOS 8.7, tvOS 15.6, macOS Monterey 12.5, Security Update 2022-005 Catalina. An app with root privileges may be able to execute arbitrary code with kernel privileges. |
| This issue was addressed with improved checks. This issue is fixed in Security Update 2022-005 Catalina, macOS Big Sur 11.6.8, macOS Monterey 12.5. Processing a maliciously crafted AppleScript binary may result in unexpected termination or disclosure of process memory. |
| A memory corruption issue was addressed with improved state management. This issue is fixed in macOS Monterey 12.5. An app may be able to execute arbitrary code with kernel privileges. |
| An out-of-bounds write issue was addressed with improved input validation. This issue is fixed in iOS 15.6 and iPadOS 15.6, watchOS 8.7, tvOS 15.6, macOS Monterey 12.5, Safari 15.6. Processing maliciously crafted web content may lead to arbitrary code execution. |
| This issue was addressed with improved checks. This issue is fixed in tvOS 15.5, watchOS 8.6, iOS 15.5 and iPadOS 15.5, macOS Monterey 12.4, macOS Big Sur 11.6.6, Security Update 2022-004 Catalina. A remote user may be able to cause a denial-of-service. |
| An out-of-bounds write issue was addressed with improved bounds checking. This issue is fixed in iOS 15.6 and iPadOS 15.6, macOS Big Sur 11.6.8, watchOS 8.7, tvOS 15.6, macOS Monterey 12.5, Security Update 2022-005 Catalina. Processing maliciously crafted web content may lead to arbitrary code execution. |
| Medtronic MyCareLink Smart 25000 is
vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device. |
| Medtronic MyCareLink Smart 25000 is
vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device |
| Medtronic MyCareLink Smart 25000 contains
an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication. |
| An issue in CosmWasm prior to v2.2.0 allows attackers to bypass capability restrictions in blockchains by exploiting a lack of runtime capability validation. This allows attackers to deploy a contract without capability enforcement, and execute unauthorized actions on the blockchain. |
| An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Remotely Dumping of Video Footage and the Live Video Stream can occur. It allows remote attackers to access and download recorded video footage from the SD card via port 9091. Additionally, attackers can connect to port 9092 to stream the live video feed by bypassing the challenge-response authentication mechanism. This exposes sensitive location and personal data. |