| In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers. |
| In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information. |
| Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. |
| In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. |
| A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area. |
| In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition. |
| Moxa EDR 810, all versions 5.1 and prior, allows an authenticated attacker to abuse the ping feature to execute unauthorized commands on the router, which may allow an attacker to perform remote code execution. |
| In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a stack-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileges. |
| In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a heap-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long command to the FTP service, which may cause memory corruption that halts the controller or leads to remote code execution and escalation of privileges. |
| In Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution. |
| Zebra Industrial Printers All Versions, Zebra printers are shipped with unrestricted end-user access to front panel options. If the option to use a passcode to limit the functionality of the front panel is applied, specially crafted packets could be sent over the same network to a port on the printer and the printer will respond with an array of information that includes the front panel passcode for the printer. Once the passcode is retrieved, an attacker must have physical access to the front panel of the printer to enter the passcode to access the full functionality of the front panel. |
| Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to network configuration to supply system commands to the server, leading to remote code execution as root. |
| Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated user, using a specially crafted URL command, to execute commands as root. |
| An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.
|
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. |
| Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. |
| Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device. |