Search

Search Results (354345 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-7574 1 Schneider-electric 3 Modicon Tm221ce16r, Modicon Tm221ce16r Firmware, Somachine 2026-05-29 10 Critical
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
CVE-2017-6030 1 Schneider-electric 6 Modicon M221, Modicon M221 Firmware, Modicon M241 and 3 more 2026-05-29 6.5 Medium
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
CVE-2025-48977 1 Apache 1 Ignite 2026-05-29 6.5 Medium
Relative Path Traversal vulnerability in Apache Ignite REST API. Authenticated REST API users can read any file on the server with "cmd=log" command and a log path crafted in a certain way. This issue affects Apache Ignite: from 2.0.0 through 2.17.0. Users are recommended to upgrade to version 2.18.0, which fixes the issue.
CVE-2026-38702 1 Inhandnetworks 8 Ir302, Ir302 Firmware, Ir305 and 5 more 2026-05-29 9.8 Critical
A command injection vulnerability exists in the Admin Access feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.
CVE-2026-38703 1 Inhandnetworks 8 Ir302, Ir302 Firmware, Ir305 and 5 more 2026-05-29 9.8 Critical
A command injection vulnerability exists in the ZeroTier VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.
CVE-2018-7798 1 Schneider-electric 2 Modicon M221, Somachine Basic 2026-05-29 8.2 High
A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device.
CVE-2026-38707 1 Inhandnetworks 8 Ir302, Ir302 Firmware, Ir305 and 5 more 2026-05-29 9.8 Critical
A command injection vulnerability exists in the IPSec VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.
CVE-2026-38704 1 Inhandnetworks 8 Ir302, Ir302 Firmware, Ir305 and 5 more 2026-05-29 9.8 Critical
A command injection vulnerability exists in the WireGuard VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.
CVE-2022-4224 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2026-05-29 8.8 High
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
CVE-2026-46526 1 Learningcircuit 1 Local Deep Research 2026-05-29 5 Medium
Local Deep Research is an AI-powered research assistant for deep, iterative research. Prior to 1.6.10, the URL checking logic in local-deep-research has a logical flaw that could be bypassed by attackers, leading to SSRF attacks. The current project uses validate_url to validate the input URL. The main logic is to perform security checks on the host portion of the URL extracted by urlparse to prevent SSRF attacks. However, there are indeed differences in parsing between urlparse and the library that actually sends the request. For example, in safe_get, validate_url is first used to perform an SSRF check, and then requests.get is used to send the actual request. This vulnerability is fixed in 1.6.10.
CVE-2022-0715 1 Schneider-electric 66 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 63 more 2026-05-29 8.9 High
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2026-49299 1 Openstack 1 Neutron 2026-05-29 N/A
In OpenStack Neutron before 28.0.1, the tagging controller enforces plural policy action names on single-tag write operations while the defined policy rules use singular names. The mismatched names evaluate as allowed under the default policy, permitting a project reader to create and update tags on same-project resources. Deployments running Neutron 26.0.0 or later are affected.
CVE-2018-7794 1 Schneider-electric 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more 2026-05-29 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
CVE-2021-33485 1 Codesys 7 Control, Control Rte, Control Runtime System Toolkit and 4 more 2026-05-29 9.8 Critical
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
CVE-2018-7792 1 Schneider-electric 2 Modicon M221, Modicon M221 Firmware 2026-05-29 7.5 High
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table.
CVE-2026-43616 1 Horsicq 2 Detect-it-easy, Die-engine 2026-05-29 7.1 High
Detect-It-Easy prior to 3.21 contains a path traversal vulnerability that allows attackers to write arbitrary files to the filesystem by crafting malicious archive entries with relative traversal sequences or absolute paths. Attackers can exploit insufficient path normalization during archive extraction to write files outside the intended extraction directory and achieve persistent code execution by overwriting user startup scripts.
CVE-2026-10007 1 Google 1 Chrome 2026-05-29 8.8 High
Use after free in SVG in Google Chrome prior to 148.0.7778.216 allowed a remote attacker to execute arbitrary code inside a sandbox via a crafted HTML page. (Chromium security severity: High)
CVE-2026-45312 1 Infiniflow 1 Ragflow 2026-05-29 9.9 Critical
RAGFlow is an open-source RAG (Retrieval-Augmented Generation) engine. In 0.24.0 and earlier, a Jinja2 template injection in the prompt generator (rag/prompts/generator.py) allows any authenticated user to execute arbitrary OS commands on the server. Any normal user can register, create a Canvas workflow with a DuckDuckGo + LLM component chain, and trigger the SSTI.
CVE-2021-22792 1 Schneider-electric 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more 2026-05-29 6.5 Medium
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).
CVE-2018-7791 1 Schneider-electric 2 Modicon M221, Modicon M221 Firmware 2026-05-29 9.8 Critical
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.