| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| ImageMagick 7.0.7-28 has a memory leak vulnerability in ReadBGRImage in coders/bgr.c. |
| ImageMagick 7.0.7-28 has a memory leak vulnerability in WritePDBImage in coders/pdb.c. |
| ImageMagick 7.0.7-28 has a memory leak vulnerability in WriteSGIImage in coders/sgi.c. |
| Aryanic HighPortal 12.5 has XSS via an Add Tags action. |
| CKEditor 4.x before 4.11.0 allows user-assisted XSS involving a source-mode paste. |
| Cross site scripting vulnerability in eDirectory prior to 9.1 SP2 |
| Cross site scripting vulnerability in iManager prior to 3.1 SP2. |
| The Snazzy Maps plugin before 1.1.5 for WordPress has XSS via the text or tab parameter. |
| The Tribulant Slideshow Gallery plugin before 1.6.6.1 for WordPress has XSS via the id, method, Gallerymessage, Galleryerror, or Galleryupdated parameter. |
| The convert_to_decimal function in vasnprintf.c in Gnulib before 2018-09-23 has a heap-based buffer overflow because memory is not allocated for a trailing '\0' character during %f processing. |
| gpsd versions 2.90 to 3.17 and microjson versions 1.0 to 1.3, an open source project, allow a stack-based buffer overflow, which may allow remote attackers to execute arbitrary code on embedded platforms via traffic on Port 2947/TCP or crafted JSON inputs. |
| A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remote code execution. |
| In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files lacking user input validation before copying data from project files onto the stack and may allow an attacker to remotely execute arbitrary code. |
| In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution. |
| All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account "default" with its default password to login to XMeye and access/view video streams. |
| InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine. |
| A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application. |
| LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution. |
| Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code. |
| LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process. |