| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices use the same hardcoded /etc/stunnel.key private key across different customers' installations, which allows remote attackers to defeat the HTTPS cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code. |
| Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0644 /var/etc/shadow (aka the /etc/shadow symlink target) permissions. |
| D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access. |
| An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user. |
| A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not). |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |
| A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |