| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| IBM Common Cryptographic Architecture (CCA) 7.5.52 and 8.4.82 could allow an unauthenticated user to execute arbitrary commands with elevated privileges on the system. |
| Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
| An issue was discovered in Grandstream GXP14XX 1.0.8.9 and GXP16XX 1.0.7.13, allows remote attackers to escalate privileges via incorrect access control using an end-user session-identity token. |
| CWE-250: Execution with Unnecessary Privileges |
| CWE-250: Execution with Unnecessary Privileges |
| Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL. |
| The Toshiba printers are vulnerable to a Local Privilege Escalation vulnerability. An attacker can remotely compromise any Toshiba printer. As for the affected products/models/versions, see the reference URL. |
| The Toshiba printers do not implement privileges separation. As for the affected products/models/versions, see the reference URL. |
| Elevation of privilege vulnerability in GE HealthCare EchoPAC products |
| SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| A Execution with Unnecessary Privileges vulnerability in lightdm-kde-greeter allows escalation from the service user to root.This issue affects lightdm-kde-greeter. before 6.0.4. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |