CVE-2026-28775 2 Datacast, International Datacasting Corporation (idc) 3 Sfx2100, Sfx2100 Firmware, Sfx2100 Series Superflex Satellitereceiver 2026-04-17 9.8 Critical
An unauthenticated Remote Code Execution (RCE) vulnerability exists in the SNMP service of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver. The deployment insecurely provisions the `private` SNMP community string with read/write access by default. Because the SNMP agent runs as root, an unauthenticated remote attacker can utilize `NET-SNMP-EXTEND-MIB` directives, abusing the fact that the system runs a vulnerable version of net-snmp pre 5.8, to execute arbitrary operating system commands with root privileges.
CVE-2026-1675 1 Wordpress 1 Wordpress 2026-04-15 5.3 Medium
The Advanced Country Blocker plugin for WordPress is vulnerable to Authorization Bypass in all versions up to, and including, 2.3.1 due to the use of a predictable default value for the secret bypass key created during installation without requiring users to change it. This makes it possible for unauthenticated attackers to bypass the geolocation blocking mechanism by appending the key to any URL on sites where the administrator has not changed the default value.
CVE-2026-26122 1 Microsoft 2 Aci Confidential Containers, Microsoft Aci Confidential Containers 2026-04-15 6.5 Medium
Initialization of a resource with an insecure default in Azure Compute Gallery allows an authorized attacker to disclose information over a network.
CVE-2026-34780 2 Electron, Electronjs 2 Electron, Electron 2026-04-15 8.4 High
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From versions 39.0.0-alpha.1 to before 39.8.0, 40.0.0-alpha.1 to before 40.7.0, and 41.0.0-alpha.1 to before 41.0.0-beta.8, apps that pass VideoFrame objects (from the WebCodecs API) across the contextBridge are vulnerable to a context isolation bypass. An attacker who can execute JavaScript in the main world (for example, via XSS) can use a bridged VideoFrame to gain access to the isolated world, including any Node.js APIs exposed to the preload script. Apps are only affected if a preload script returns, resolves, or passes a VideoFrame object to the main world via contextBridge.exposeInMainWorld(). Apps that do not bridge VideoFrame objects are not affected. This issue has been patched in versions 39.8.0, 40.7.0, and 41.0.0-beta.8.
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVE-2025-1863 2026-04-15 9.8 Critical
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2024-47295 1 Seiko Epson Corporation 1 Web Config 2026-04-15 8.1 High
Insecure initial password configuration issue in SEIKO EPSON Web Config allows a remote unauthenticated attacker to set an arbitrary password and operate the device with an administrative privilege. As for the details of the affected versions, see the information provided by the vendor under [References].
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2019-25219 1 Asio 1 Cplusplus Library 2026-04-15 7.5 High
Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-14758 1 Alasca 1 Yaook 2026-04-15 6.5 Medium