| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper access restrictions in HCL BigFix Remote Control Server WebUI (versions 10.1.0.0248 and lower) allow non-admin users to view unauthorized information on certain web pages. |
| The affected products expose an unauthenticated Telnet-based command line interface that could allow an attacker to modify hardware configurations, manipulate data, or factory reset the device. |
| Unexpected authentication form rendering in HTML Form Adapter using only non-default redirectless mode in PingFederate allows authentication attempts which may enable brute force login attacks. |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| The devices do not implement any authentication for the web interface or the MQTT server. An attacker who has network access to the device immediately gets administrative access to the devices and can perform arbitrary administrative actions and reconfigure the devices or potentially gain access to sensitive data. |
| Ash Authentication provides authentication for the Ash framework. The confirmation flow for account creation currently uses a GET request triggered by clicking a link sent via email. Some email clients and security tools (e.g., Outlook, virus scanners, and email previewers) may automatically follow these links, unintentionally confirming the account. This allows an attacker to register an account using another user’s email and potentially have it auto-confirmed by the victim’s email client. This does not allow attackers to take over or access existing accounts or private data. It is limited to account confirmation of new accounts only. This vulnerability is fixed in 4.7.0. |
| A directory traversal vulnerability exists in ColoradoFTP Server ≤ 1.3 Build 8 for Windows, allowing unauthenticated attackers to read or write arbitrary files outside the configured FTP root directory. The flaw is due to insufficient sanitation of user-supplied file paths in the FTP GET and PUT command handlers. Exploitation is possible by submitting traversal sequences during FTP operations, enabling access to system-sensitive files. This issue affects only the Windows version of ColoradoFTP. |
| An authenticated command injection vulnerability exists in Tiki Wiki CMS versions ≤14.1, ≤12.4 LTS, ≤9.10 LTS, and ≤6.14 via the `viewmode` GET parameter in `tiki-calendar.php`. When the calendar module is enabled and an authenticated user has permission to access it, an attacker can inject and execute arbitrary PHP code. Successful exploitation leads to remote code execution in the context of the web server user. |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code. |
| A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges.
Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client.
This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3 |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| An unauthenticated command injection vulnerability exists in WePresent WiPG-1000 firmware versions prior to 2.2.3.0, due to improper input handling in the undocumented /cgi-bin/rdfs.cgi endpoint. The Client parameter is not sanitized before being passed to a system call, allowing an unauthenticated remote attacker to execute arbitrary commands as the web server user. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |