| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Owl Labs Meeting Owl 5.2.0.15 allows attackers to deactivate the passcode protection mechanism via a certain c 11 message. |
| An issue in TopIDP3000 Topsec Operating System tos_3.3.005.665b.15_smpidp allows attackers to perform a brute-force attack via a crafted session_id cookie. |
| In Montala ResourceSpace through 9.8 before r19636, csv_export_results_metadata.php allows attackers to export collection metadata via a non-NULL k value. |
| Dell EMC PowerStore, contain(s) an Improper Restriction of Excessive Authentication Attempts Vulnerability in PowerStore Manager GUI. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users. |
| Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service. |
| Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position. |
| An insufficient logging [CWE-778] vulnerability in FortiSandbox versions 4.0.0 to 4.0.2, 3.2.0 to 3.2.3 and 3.1.0 to 3.1.5 and FortiDeceptor versions 4.2.0, 4.1.0 through 4.1.1, 4.0.0 through 4.0.2, 3.3.0 through 3.3.3, 3.2.0 through 3.2.2,3.1.0 through 3.1.1 and 3.0.0 through 3.0.2 may allow a remote attacker to repeatedly enter incorrect credentials without causing a log entry, and with no limit on the number of failed authentication attempts. |
| The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| An attacker can freely brute force username and password and can takeover any account. An attacker could easily guess user passwords and gain access to user and administrative accounts. |
| Missing Critical Step in Authentication in GitHub repository namelessmc/nameless prior to v2.0.2. |
| Authentication Bypass by Primary Weakness in GitHub repository bookwyrm-social/bookwyrm prior to 0.4.5. |
| The Duplicator WordPress plugin before 1.4.7 does not authenticate or authorize visitors before displaying information about the system such as server software, php version and full file system path to the site. |
| Improper Restriction of Excessive Authentication Attempts in GitHub repository heroiclabs/nakama prior to 3.13.0. This results in login brute-force attacks. |
| Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password. |
| The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default). |
| The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. |
| Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. |
| JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. |
| USU Oracle Optimization before 5.17.5 lacks Polkit authentication, which allows smartcollector users to achieve root access via pkexec. NOTE: this is not an Oracle Corporation product. |