| CVE-2021-43938 | 1 Smartptt | 1 Scada Server | 2025-04-16 | 8.1 High |
| Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization. | ||||
| CVE-2022-1358 | 1 Cambiumnetworks | 1 Cnmaestro | 2025-04-16 | 5.9 Medium |
| The affected On-Premise is vulnerable to data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate and dump all data held in the cnMaestro database. | ||||
| CVE-2022-1361 | 1 Cambiumnetworks | 1 Cnmaestro | 2025-04-16 | 7.4 High |
| The affected On-Premise cnMaestro is vulnerable to a pre-auth data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate data about other user’s accounts and devices. | ||||
| CVE-2021-32965 | 1 Deltaww | 1 Diascreen | 2025-04-16 | 7.8 High |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2022-28690 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to an out-of-bounds write via uninitialized pointer, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-29488 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to an out-of-bounds read via uninitialized pointer, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-30540 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to a heap-based buffer overflow via uninitialized pointer, which may allow an attacker to execute arbitrary code | ||||
| CVE-2022-2136 | 1 Advantech | 1 Iview | 2025-04-16 | 8.8 High |
| The affected product is vulnerable to multiple SQL injections that require low privileges for exploitation and may allow an unauthorized attacker to disclose information. | ||||
| CVE-2022-2142 | 1 Advantech | 1 Iview | 2025-04-16 | 8.1 High |
| The affected product is vulnerable to a SQL injection with high attack complexity, which may allow an unauthorized attacker to disclose information. | ||||
| CVE-2022-2894 | 1 Measuresoft | 1 Scadapro Server | 2025-04-16 | 7.8 High |
| Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file. | ||||
| CVE-2022-40967 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41773 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41133 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-3378 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory write. | ||||
| CVE-2022-3377 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 6 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory read. | ||||
| CVE-2022-43447 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-43452 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-41775 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-43506 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-2002 | 1 Ge | 1 Cimplicity | 2025-04-16 | 7.8 High |
| GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. | ||||