Export limit exceeded: 95916 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (95916 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-22987 | 1 Advantech | 2 Adam-3600, Adam-3600 Firmware | 2025-04-16 | 9.8 Critical |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. | ||||
| CVE-2022-21143 | 1 Airspan | 9 A5x, A5x Firmware, C5c and 6 more | 2025-04-16 | 7.5 High |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not properly sanitize user input on several locations, which may allow an attacker to inject arbitrary commands. | ||||
| CVE-2022-21146 | 1 Ipcomm | 2 Ipdio, Ipdio Firmware | 2025-04-16 | 6.3 Medium |
| Persistent cross-site scripting in the web interface of ipDIO allows an unauthenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into a specific parameter. The XSS payload will be executed when a legitimate user attempts to review history. | ||||
| CVE-2022-24432 | 1 Ipcomm | 2 Ipdio, Ipdio Firmware | 2025-04-16 | 5.5 Medium |
| Persistent cross-site scripting (XSS) in the web interface of ipDIO allows an authenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into specific fields. The XSS payload will be executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services). | ||||
| CVE-2021-27416 | 1 Hitachienergy | 1 Ellipse Enterprise Asset Management | 2025-04-16 | 5.5 Medium |
| An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session. | ||||
| CVE-2022-25246 | 1 Ptc | 2 Axeda Agent, Axeda Desktop Server | 2025-04-16 | 9.8 Critical |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. | ||||
| CVE-2022-25252 | 1 Ptc | 2 Axeda Agent, Axeda Desktop Server | 2025-04-16 | 7.5 High |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) when receiving certain input throws an exception. Services using said function do not handle the exception. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to crash the affected product. | ||||
| CVE-2020-25180 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2025-04-16 | 5.3 Medium |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. | ||||
| CVE-2020-25193 | 1 Ge | 6 Rt430, Rt430 Firmware, Rt431 and 3 more | 2025-04-16 | 5.3 Medium |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. | ||||
| CVE-2021-27418 | 1 Ge | 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more | 2025-04-16 | 5.3 Medium |
| GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. | ||||
| CVE-2021-27476 | 1 Rockwellautomation | 1 Factorytalk Assetcentre | 2025-04-16 | 10 Critical |
| A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier. | ||||
| CVE-2021-32933 | 1 Auvesy-mdt | 2 Autosave, Autosave For System Platform | 2025-04-16 | 10 Critical |
| An attacker could leverage an API to pass along a malicious file that could then manipulate the process creation command line in MDT AutoSave versions prior to v6.02.06 and run a command line argument. This could then be leveraged to run a malicious process. | ||||
| CVE-2021-32974 | 1 Moxa | 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more | 2025-04-16 | 9.8 Critical |
| Improper input validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to execute commands. | ||||
| CVE-2021-32976 | 1 Moxa | 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more | 2025-04-16 | 9.8 Critical |
| Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code. | ||||
| CVE-2022-1068 | 1 Modbustools | 1 Modbus Slave | 2025-04-16 | 5.5 Medium |
| Modbus Tools Modbus Slave (versions 7.4.2 and prior) is vulnerable to a stack-based buffer overflow in the registration field. This may cause the program to crash when a long character string is used. | ||||
| CVE-2022-21155 | 4 Apple, Fernhillsoftware, Linux and 1 more | 4 Macos, Scada Server, Linux Kernel and 1 more | 2025-04-16 | 7.5 High |
| A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit. | ||||
| CVE-2020-25158 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 7.6 High |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. | ||||
| CVE-2020-25164 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 6.5 Medium |
| A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface. | ||||
| CVE-2020-25168 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 3.3 Low |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. | ||||
| CVE-2021-32927 | 1 Uffizio | 1 Gps Tracker | 2025-04-16 | 7.1 High |
| An attacker may be able to inject client-side JavaScript code on multiple instances within all versions of Uffizio GPS Tracker. | ||||