Export limit exceeded: 424710 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 95145 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (95145 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-38942 | 1 Dango | 1 Dango-translator | 2024-11-21 | 9.8 Critical |
| Dango-Translator v4.5.5 was discovered to contain a remote command execution (RCE) vulnerability via the component app/config/cloud_config.json. | ||||
| CVE-2023-38941 | 1 Ehco1996 | 1 Django-sspanel | 2024-11-21 | 9.8 Critical |
| django-sspanel v2022.2.2 was discovered to contain a remote command execution (RCE) vulnerability via the component sspanel/admin_view.py -> GoodsCreateView._post. | ||||
| CVE-2023-38940 | 1 Tenda | 6 F1203, F1203 Firmware, Fh1203 and 3 more | 2024-11-21 | 9.8 Critical |
| Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | ||||
| CVE-2023-38939 | 1 Tenda | 4 F1202, F1202 Firmware, Fh1202 and 1 more | 2024-11-21 | 9.8 Critical |
| Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. | ||||
| CVE-2023-38938 | 1 Tenda | 8 F1202, F1202 Firmware, Fh1202 and 5 more | 2024-11-21 | 9.8 Critical |
| Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im. | ||||
| CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | 9.8 Critical |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | ||||
| CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-11-21 | 9.8 Critical |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | ||||
| CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2024-11-21 | 9.8 Critical |
| Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | ||||
| CVE-2023-38934 | 1 Tenda | 6 F1203, F1203 Firmware, Fh1203 and 3 more | 2024-11-21 | 9.8 Critical |
| Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. | ||||
| CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-11-21 | 9.8 Critical |
| Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | ||||
| CVE-2023-38932 | 1 Tenda | 8 F1202, F1202 Firmware, Fh1202 and 5 more | 2024-11-21 | 9.8 Critical |
| Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function. | ||||
| CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2024-11-21 | 9.8 Critical |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | ||||
| CVE-2023-38930 | 1 Tenda | 10 Ac5, Ac5 Firmware, Ac7 and 7 more | 2024-11-21 | 9.8 Critical |
| Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | ||||
| CVE-2023-38929 | 1 Tenda | 2 4g300, 4g300 Firmware | 2024-11-21 | 9.8 Critical |
| Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer. | ||||
| CVE-2023-38928 | 1 Netgear | 2 R7100lg, R7100lg Firmware | 2024-11-21 | 9.8 Critical |
| Netgear R7100LG 1.0.0.78 was discovered to contain a command injection vulnerability via the password parameter at usb_remote_invite.cgi. | ||||
| CVE-2023-38921 | 1 Netgear | 4 Wag302v2, Wag302v2 Firmware, Wg302v2 and 1 more | 2024-11-21 | 8.8 High |
| Netgear WG302v2 v5.2.9 and WAG302v2 v5.1.19 were discovered to contain multiple command injection vulnerabilities in the upgrade_handler function via the firmwareRestore and firmwareServerip parameters. | ||||
| CVE-2023-38911 | 1 Cszcms | 1 Csz Cms | 2024-11-21 | 5.4 Medium |
| A Cross-Site Scripting (XSS) vulnerability in CSZ CMS 1.3.0 allows attackers to execute arbitrary code via a crafted payload to the Gallery parameter in the YouTube URL fields. | ||||
| CVE-2023-38910 | 1 Cszcms | 1 Csz Cms | 2024-11-21 | 6.1 Medium |
| CSZ CMS 1.3.0 is vulnerable to cross-site scripting (XSS), which allows attackers to execute arbitrary web scripts or HTML via a crafted payload entered in the 'Carousel Wiget' section and choosing our carousel widget created above, in 'Photo URL' and 'YouTube URL' plugin. | ||||
| CVE-2023-38904 | 1 Decapcms | 1 Netlify Cms | 2024-11-21 | 5.4 Medium |
| A Cross Site Scripting (XSS) vulnerability in Netlify CMS v.2.10.192 allows a remote attacker to execute arbitrary code via a crafted payload to the body parameter of the new post function. | ||||
| CVE-2023-38902 | 1 Ruijie | 197 Nbc Series Wireless Controllers, Rg-eap101, Rg-eap101 Firmware and 194 more | 2024-11-21 | 8.8 High |
| A command injection vulnerability in RG-EW series home routers and repeaters v.EW_3.0(1)B11P219, RG-NBS and RG-S1930 series switches v.SWITCH_3.0(1)B11P219, RG-EG series business VPN routers v.EG_3.0(1)B11P219, EAP and RAP series wireless access points v.AP_3.0(1)B11P219, and NBC series wireless controllers v.AC_3.0(1)B11P219 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /cgi-bin/luci/api/cmd via the remoteIp field. | ||||