Export limit exceeded: 94694 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (94694 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-25807 | 1 Igel | 1 Universal Management Suite | 2024-11-21 | 5.5 Medium |
| An issue was discovered in the IGEL Universal Management Suite (UMS) 6.07.100. A hardcoded DES key in the LDAPDesPWEncrypter class allows an attacker, who has discovered encrypted LDAP bind credentials, to decrypt those credentials using a static 8-byte DES key. | ||||
| CVE-2022-25806 | 1 Igel | 1 Universal Management Suite | 2024-11-21 | 8.8 High |
| An issue was discovered in the IGEL Universal Management Suite (UMS) 6.07.100. A hardcoded DES key in the PrefDBCredentials class allows an attacker, who has discovered encrypted superuser credentials, to decrypt those credentials using a static 8-byte DES key. | ||||
| CVE-2022-25802 | 1 Bestpractical | 1 Request Tracker | 2024-11-21 | 6.1 Medium |
| Best Practical Request Tracker (RT) before 4.4.6 and 5.x before 5.0.3 allows XSS via a crafted content type for an attachment. | ||||
| CVE-2022-25797 | 1 Autodesk | 1 Dwg Trueview | 2024-11-21 | 7.8 High |
| A maliciously crafted PDF file in Autodesk AutoCAD 2022, 2021, 2020, 2019 can be used to dereference for a write beyond the allocated buffer while parsing PDF files. The vulnerability exists because the application fails to handle a crafted PDF file, which causes an unhandled exception. | ||||
| CVE-2022-25795 | 1 Autodesk | 1 Autocad | 2024-11-21 | 7.8 High |
| A Memory Corruption Vulnerability in Autodesk TrueView 2022 and 2021 may lead to remote code execution through maliciously crafted DWG files. | ||||
| CVE-2022-25792 | 1 Autodesk | 11 Advance Steel, Autocad, Autocad Architecture and 8 more | 2024-11-21 | 7.8 High |
| A maliciously crafted DXF file in Autodesk AutoCAD 2022, 2021, 2020, 2019 and Autodesk Navisworks 2022 can be used to write beyond the allocated buffer through Buffer overflow vulnerability. This vulnerability can be exploited to execute arbitrary code. | ||||
| CVE-2022-25791 | 1 Autodesk | 11 Advance Steel, Autocad, Autocad Architecture and 8 more | 2024-11-21 | 7.8 High |
| A Memory Corruption vulnerability for DWF and DWFX files in Autodesk AutoCAD 2022, 2021, 2020, 2019 and Autodesk Navisworks 2022 may lead to code execution through maliciously crafted DLL files. | ||||
| CVE-2022-25790 | 1 Autodesk | 11 Advance Steel, Autocad, Autocad Architecture and 8 more | 2024-11-21 | 7.8 High |
| A maliciously crafted DWF file in Autodesk AutoCAD 2022, 2021, 2020, 2019 and Autodesk Navisworks 2022 can be used to write beyond the allocated boundaries when parsing the DWF files. Exploitation of this vulnerability may lead to code execution. | ||||
| CVE-2022-25785 | 1 Secomea | 18 Sitemanager 1129, Sitemanager 1129 Firmware, Sitemanager 1139 and 15 more | 2024-11-21 | 6.6 Medium |
| Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7. | ||||
| CVE-2022-25784 | 1 Secomea | 18 Sitemanager 1129, Sitemanager 1129 Firmware, Sitemanager 1139 and 15 more | 2024-11-21 | 9.1 Critical |
| Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. This issue affects: Secomea SiteManager all versions prior to 9.7. | ||||
| CVE-2022-25783 | 1 Secomea | 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more | 2024-11-21 | 4.3 Medium |
| Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7. | ||||
| CVE-2022-25781 | 1 Secomea | 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more | 2024-11-21 | 4.2 Medium |
| Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session. | ||||
| CVE-2022-25779 | 1 Secomea | 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more | 2024-11-21 | 4.3 Medium |
| Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7. | ||||
| CVE-2022-25772 | 1 Acquia | 1 Mautic | 2024-11-21 | 9.6 Critical |
| A cross-site scripting (XSS) vulnerability in the web tracking component of Mautic before 4.3.0 allows remote attackers to inject executable javascript | ||||
| CVE-2022-25761 | 2 Fedoraproject, Open62541 | 2 Fedora, Open62541 | 2024-11-21 | 7.5 High |
| The package open62541/open62541 before 1.2.5, from 1.3-rc1 and before 1.3.1 are vulnerable to Denial of Service (DoS) due to a missing limitation on the number of received chunks - per single session or in total for all concurrent sessions. An attacker can exploit this vulnerability by sending an unlimited number of huge chunks (e.g. 2GB each) without sending the Final closing chunk. | ||||
| CVE-2022-25756 | 1 Siemens | 48 Scalance X302-7eec, Scalance X302-7eec Firmware, Scalance X304-2fe and 45 more | 2024-11-21 | 6.1 Medium |
| A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. | ||||
| CVE-2022-25753 | 1 Siemens | 48 Scalance X302-7eec, Scalance X302-7eec Firmware, Scalance X304-2fe and 45 more | 2024-11-21 | 8.8 High |
| A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device. | ||||
| CVE-2022-25740 | 1 Qualcomm | 24 Mdm8207, Mdm8207 Firmware, Mdm9205 and 21 more | 2024-11-21 | 9.8 Critical |
| Memory corruption in modem due to buffer overwrite while building an IPv6 multicast address based on the MAC address of the iface | ||||
| CVE-2022-25729 | 1 Qualcomm | 60 Ar8031, Ar8031 Firmware, Csra6620 and 57 more | 2024-11-21 | 9.8 Critical |
| Memory corruption in modem due to improper length check while copying into memory | ||||
| CVE-2022-25678 | 1 Qualcomm | 24 Mdm8207, Mdm8207 Firmware, Mdm9205 and 21 more | 2024-11-21 | 9.8 Critical |
| Memory correction in modem due to buffer overwrite during coap connection | ||||