Export limit exceeded: 105481 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (105481 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-4239 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4240 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4241 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4242 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4243 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4244 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4245 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4246 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4497 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4247 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4252 | 1 Tenda | 2 I22, I22 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2022-40196 | 1 Intel | 1 Oneapi Dpc\+\+\/c\+\+ Compiler | 2025-01-27 | 7.8 High |
| Improper access control in the Intel(R) oneAPI DPC++/C++ Compiler before version 2022.2.1 and Intel C++ Compiler Classic before version 2021.7.1 for some Intel(R) oneAPI Toolkits before version 2022.3.1 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-4248 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2022-25987 | 1 Intel | 2 C\+\+ Compiler Classic, Oneapi Toolkits | 2025-01-27 | 8.3 High |
| Improper handling of Unicode encoding in source code to be compiled by the Intel(R) C++ Compiler Classic before version 2021.6 for Intel(R) oneAPI Toolkits before version 2022.2 may allow an unauthenticated user to potentially enable escalation of privilege via network access. | ||||
| CVE-2022-26843 | 1 Intel | 2 Oneapi Dpc\+\+\/c\+\+ Compiler, Oneapi Toolkits | 2025-01-27 | 8.3 High |
| Insufficient visual distinction of homoglyphs presented to user in the Intel(R) oneAPI DPC++/C++ Compiler before version 2022.1 for Intel(R) oneAPI Toolkits before version 2022.2 may allow an unauthenticated user to potentially enable escalation of privilege via network access. | ||||
| CVE-2024-4249 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2022-25992 | 1 Intel | 1 Oneapi-cli | 2025-01-27 | 7.5 High |
| Insecure inherited permissions in the Intel(R) oneAPI Toolkits oneapi-cli before version 0.2.0 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-4250 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2022-33892 | 1 Intel | 1 Quartus Prime | 2025-01-27 | 7.3 High |
| Path traversal in the Intel(R) Quartus Prime Pro and Standard edition software may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2022-33902 | 1 Intel | 1 Quartus Prime | 2025-01-27 | 7.3 High |
| Insufficient control flow management in the Intel(R) Quartus Prime Pro and Standard edition software may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||