Export limit exceeded: 421176 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 94609 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (94609 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-25667 1 Siemens 30 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 27 more 2026-06-02 6.5 Medium
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
CVE-2021-25662 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2026-06-02 7.5 High
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
CVE-2021-25661 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2026-06-02 7.5 High
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
CVE-2021-25660 1 Siemens 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more 2026-06-02 7.5 High
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
CVE-2015-6477 1 Nordex 1 Nordex Control 2 Scada 2026-06-02 6.1 Medium
Multiple cross-site scripting (XSS) vulnerabilities in the Wind Farm Portal application in Nordex Control 2 (NC2) SCADA 16 and earlier allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2026-9024 1 Dassault 1 Delmia Service Process Engineer 2026-06-02 8.7 High
A Stored Cross-site Scripting (XSS) vulnerability affecting Process Experience Studio in DELMIA Service Process Engineer from Release 3DEXPERIENCE R2024x through Release 3DEXPERIENCE R2026x could allow an attacker to execute arbitrary script code in user's browser session.
CVE-2026-42683 2 Vikwp, Wordpress 2 Vikbooking Hotel Booking Engine & Pms, Wordpress 2026-06-02 7.1 High
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in e4jvikwp VikBooking Hotel Booking Engine & PMS allows DOM-Based XSS. This issue affects VikBooking Hotel Booking Engine & PMS: from n/a through 1.8.8.
CVE-2026-42681 2 E2pdf, Wordpress 2 E2pdf, Wordpress 2026-06-02 7.1 High
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in E2Pdf.Com e2pdf allows Reflected XSS. This issue affects e2pdf: from n/a through 1.32.14.
CVE-2026-44466 2 Zed, Zed-industries 2 Zed, Zed 2026-06-02 8.6 High
Zed is a code editor. Prior to 0.229.0, Zed's terminal tool permission system can be bypassed via bash arithmetic expansion $((...)), allowing execution of arbitrary commands nested inside an allowlisted command like echo. This vulnerability is fixed in 0.229.0.
CVE-2025-3633 1 Ibm 2 Cognos Analytics, Cognos Transformer 2026-06-02 5.4 Medium
IBM Cognos Analytics 11.2.0, 11.2.4, 12.0, and 12.1.0 and IBM Cognos Transformer 11.2.4, 12.0, and 12.1.0 are vulnerable to cross-site scripting (XSS). This vulnerability allows a remote attacker to inject arbitrary JavaScript code into the web user interface, which may alter the intended functionality and could lead to the disclosure of credentials within a trusted session.
CVE-2026-1718 2 Ibm, Linux 3 Db2, Linux On Ibm Z, Linux Kernel 2026-06-02 7.1 High
IBM Db2 11.5.0 through 11.5.9, and 12.1.0 through 12.1.4 is vulnerable to a denial of service with a specially crafted query when autonomous transactions are enabled.
CVE-2026-23862 1 Dell 1 Thinos 2026-06-02 7.8 High
Dell ThinOS 10 versions prior to ThinOS 2602_10.0573, contain an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.
CVE-2026-28383 1 Grafana 1 Grafana 2026-06-02 6.5 Medium
A request to the Grafana plugin resources endpoint can cause unbounded memory allocation by reading the entire request body into memory. An authenticated user can exploit this to trigger an out-of-memory condition, potentially causing a denial of service.
CVE-2021-27384 1 Siemens 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more 2026-06-02 9.8 Critical
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
CVE-2025-27852 1 Garmin 3 Empirbus Wireless Display Unit, Empirbus Wireless Display Unit Firmware, Wdu 2026-06-02 5 Medium
The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows a reflected cross site scripting (XSS) attack. This allows an attacker on the local network segment to execute arbitrary JavaScript code within the context of the WDU webpage. Full administrator level access to the device is possible. To initiate an exploit of this vulnerability, the victim must execute two actions: (1) view a specific URL served by the WDU, and (2) click an element on the rendered page.
CVE-2026-45392 1 Cribl 1 Cribl Stream 2026-06-02 8.7 High
DOM-based cross-site scripting (XSS) in Cribl Stream before 4.17.1 allows a remote attacker to execute arbitrary JavaScript in the browser of an authenticated user who is tricked into visiting a crafted URL and interacting with the page.
CVE-2017-14850 1 Orpak 1 Siteomat 2026-06-02 6.1 Medium
All known versions of the Orpak SiteOmat web management console is vulnerable to multiple instances of Stored Cross-site Scripting due to improper external user-input validation. An attacker with access to the web interface is able to hijack sessions or navigate victims outside of SiteOmat, to a malicious server owned by him.
CVE-2017-14728 1 Orpak 1 Siteomat 2026-06-02 9.8 Critical
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
CVE-2026-48862 1 Elixir-mint 1 Mint 2026-06-02 N/A
Allocation of Resources Without Limits or Throttling vulnerability in elixir-mint Mint allows attacker-controlled HTTP/2 servers to exhaust memory in a Mint client via PUSH_PROMISE flooding. In lib/mint/http2.ex, Mint.HTTP2.decode_push_promise_headers_and_add_response/5 inserts a :reserved_remote entry into conn.streams for every promised stream ID. The neighbouring Mint.HTTP2.assert_valid_promised_stream_id/2 only verifies that the promised ID is even and not already present; client_settings.max_concurrent_streams is not consulted at promise time. The concurrency cap is only checked when the response HEADERS for the promised stream arrive, so a server that emits PUSH_PROMISE frames and withholds the matching HEADERS never trips that check. HTTP/2 server push is accepted by default (client_settings.enable_push defaults to true). A single long-lived HTTP/2 connection to a hostile server lets that server pin one conn.streams entry per PUSH_PROMISE frame it sends, with no upper bound, until the client process runs out of memory. This issue affects mint: from 0.2.0 before 1.9.0.
CVE-2026-49754 1 Elixir-mint 1 Mint 2026-06-02 N/A
Allocation of Resources Without Limits or Throttling vulnerability in elixir-mint Mint allows attacker-controlled HTTP/2 servers to exhaust memory in a Mint client (HTTP/2 CONTINUATION flood). When Mint's HTTP/2 receive path observes a HEADERS frame without the END_HEADERS flag, the unparsed header-block fragment is parked in conn.headers_being_processed, and every subsequent CONTINUATION frame on that stream is appended to the accumulator. Nothing in the receive path caps the accumulator: there is no per-stream size limit, no CONTINUATION frame-count limit, and max_header_list_size is only enforced on outgoing requests, never on inbound header blocks (its default is :infinity). A malicious or compromised HTTP/2 server can stream an endless sequence of CONTINUATION frames (each up to the peer-advertised SETTINGS_MAX_FRAME_SIZE) and drive the client's iolist to arbitrary size, causing memory exhaustion and BEAM process death. A single connection to an attacker-controlled HTTP/2 endpoint is sufficient. This issue affects mint: from 0.1.0 before 1.9.0.