Metrics
Affected Vendors & Products
Wed, 12 Aug 2026 20:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Wed, 12 Aug 2026 00:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Unauthenticated Node‑RED Interface Enables Remote Code Execution on Siemens SIMATIC IoT2050 Advanced |
Tue, 11 Aug 2026 12:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges. | |
| Weaknesses | CWE-306 | |
| References |
| |
| Metrics |
cvssV3_1
|
Status: PUBLISHED
Assigner: siemens
Published:
Updated: 2026-08-12T19:19:54.001Z
Reserved: 2026-06-29T12:59:54.795Z
Link: CVE-2026-58115
Updated: 2026-08-12T17:59:39.112Z
Status : Received
Published: 2026-08-11T13:19:00.190
Modified: 2026-08-12T20:17:45.377
Link: CVE-2026-58115
No data.
OpenCVE Enrichment
Updated: 2026-08-12T00:00:03Z