There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.
Metrics
Affected Vendors & Products
References
History
Fri, 19 Jun 2026 18:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions. | |
| Title | Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen | |
| First Time appeared |
Ni
Ni grpc-device Ni instrumentstudio |
|
| Weaknesses | CWE-681 | |
| CPEs | cpe:2.3:a:ni:grpc-device:*:*:*:*:*:*:*:* cpe:2.3:a:ni:instrumentstudio:*:*:*:*:*:*:*:* |
|
| Vendors & Products |
Ni
Ni grpc-device Ni instrumentstudio |
|
| References |
| |
| Metrics |
cvssV3_1
|
Status: PUBLISHED
Assigner: NI
Published:
Updated: 2026-06-19T13:48:44.874Z
Reserved: 2026-05-20T19:52:00.357Z
Link: CVE-2026-9143
No data.
No data.
No data.
OpenCVE Enrichment